636
SIEPCYEUOQ2V01A Q2V Technical Manual
■
L1-08: oL1 Current Level
No.
(Hex.)
Name
Description
Default
(Range)
L1-08
(1103)
oL1 Current Level
Sets the reference current for the motor 1 thermal overload detection. When the current level > 0.0
A, you cannot set this value < 10% of drive rated current.
0.0 A
(0.0 A or 10% to 150% of
the drive rated current)
When
L1-08 = 0.0 A
, the drive uses
E2-01 [Mot Rated Current (FLA)]
to detect the motor overload protection. In
PM control mode, the drive uses
E5-03 [PM Mot Rated Current (FLA)]
to detect the motor overload protection.
When
L1-08 ≠ 0.0 A
, the set value is the reference for motor overload protection.
Note:
•
Display is in these units:
–
0.01 A: 2001 to 2042, B001 to B018, 4001 to 4023
–
0.1 A: 2056 to 2082, 4031 to 4060
•
When the current level > 0.0 A, you cannot set this value < 10% of drive rated current.
■
L1-09: M2 oL1 Curr.Level
No.
(Hex.)
Name
Description
Default
(Range)
L1-09
(1104)
M2 oL1 Curr.Level
Sets the reference current for the motor 2 thermal overload detection. When the current level > 0.0
A, you cannot set this value < 10% of drive rated current.
0.0 A
(0.0 A or 10 to150% of the
drive rated current)
When
L1-09 = 0.0 A
, the drive uses
E4-01 [M2 Rated Current (FLA)]
to detect the motor overload protection.
When
L1-09 ≠ 0.0 A
, the set value is the reference for motor overload protection.
Note:
•
Display is in these units:
–
0.01 A: 2001 to 2042, B001 to B018, 4001 to 4023
–
0.1 A: 2056 to 2082, 4031 to 4060
•
When the current level > 0.0 A, you cannot set this value < 10% of drive rated current.
■
L1-13: Motor oL1 Memory Selection
No.
(Hex.)
Name
Description
Default
(Range)
L1-13
(046D)
Motor oL1 Memory
Selection
Sets the function that keeps the current electronic thermal protector value when the drive stops
receiving power.
1
(0, 1)
0 : Disabled
1 : Enabled
Sets if the drive will calculate the motor again when the drive is energized again.
■
L1-22: LeakCurrFil Tim1
No.
(Hex.)
Name
Description
Default
(Range)
L1-22
(0768)
RUN
LeakCurrFil Tim1
Sets the leakage current detection reduction filter time constant during constant speed run.
Determined by C6-02
(0.0 - 60.0 s)
Note:
You can set this parameter when
C6-02 = B [Carrier Frequency Selection = Leakage Current Rejection PWM]
.
If incorrect detection of alarms, for example
oL1 [Motor Overload]
, occur or errors occur in the values on the
current monitor because of a leakage current, increase the setting value.
■
L1-23: LeakCurrFil Tim2
No.
(Hex.)
Name
Description
Default
(Range)
L1-23
(0769)
RUN
LeakCurrFil Tim2
Sets the leakage current detection reduction filter time constant during acceleration/deceleration.
Determined by C6-02
(0.0 - 60.0 s)
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for Q2V Series
Page 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Page 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Page 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...