718
SIEPCYEUOQ2V01A Q2V Technical Manual
Note:
To get the same qualities as a Yaskawa 1000-series drive or previous series drive, set this parameter =
T1-03 [Motor Rated Voltage]
.
◆
T2: PM MOTOR
T2 parameters
set the Auto-Tuning input data for PM motor tuning.
Note:
The drive automatically sets these PM motor parameters:
•
E1: V/F PARAMETER MOTOR 1
•
E5: PM MOTOR SETTINGS
■
T2-01: PM AutoTune Mode Select
No.
(Hex.)
Name
Description
Default
(Range)
T2-01
(0750)
PM AutoTune Mode Select
Sets the type of Auto-Tuning for PM motors.
0
(Determined by A1-02)
Note:
The manufacturer recommends Rotational (Ld, Lq, R, back-EMF) for specialized motors. Rotational Auto-Tuning rotates the motor to
measure the actual induction voltage constants for more accurate control than Stationary Auto-Tuning.
0 : PM Motor Parameter Settings
1 : PM Static Full AutoTune
2 : PM Static R Autotune
4 : PM Rotary Autotune
5 : High Frequency Injection
■
T2-02: PMMot Code Selection
No.
(Hex.)
Name
Description
Default
(Range)
T2-02
(0751)
PMMot Code Selection
If the drive is operating an SMRD, SMRA, or SSR1 series Yaskawa PM motor, enter the PM
motor code in to align with the rotation speed and motor output.
Determined by A1-02 and
o2-04
(0000 - FFFF)
Enter the motor code to automatically set parameters
T2-03 to T2-14
. When you are operating a specialized motor
or a non-Yaskawa motor, set
T2-02 = FFFF
and enter the data from the motor nameplate or the motor test report.
You can only enter the permitted PM motor codes. Different drive control methods will accept different PM motor
codes.
■
T2-03: PMMot Motor Type
No.
(Hex.)
Name
Description
Default
(Range)
T2-03
(0752)
PMMot Motor Type
Sets the type of PM motor the drive will operate.
1
(0, 1)
0 : IPM Motor
1 : SPM Motor
■
T2-04: PMMot Rated Power
No.
(Hex.)
Name
Description
Default
(Range)
T2-04
(0730)
PMMot Rated Power
Uses the units set in
o1-58 [Mot Capacity Unit]
to set the PM motor rated output power.
Determined by o2-04, C6-
01
(0.00 - 650.00 kW)
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for Q2V Series
Page 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Page 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Page 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...