76
SIEPCYEUOQ2V01A Q2V Technical Manual
Table 3.6 Safe Disable Input
Terminal
Name (Default)
Function (Signal Level)
H1
Safe Disable input 1
Remove the jumper between terminals H1-HC and H2-HC to use the Safe Disable input.
•
24 V, 6 mA
•
ON: Normal operation
•
OFF: Coasting motor
•
Internal impedance 4.7 kΩ
•
OFF Minimum OFF time of 3 ms.
H2
Safe Disable input 2
HC
Safe Disable function common
Safe Disable function common
NOTICE:
Do not close the circuit between terminals HC and D0V. A closed
circuit between these terminals will cause damage to the drive.
Table 3.7 Master Frequency Reference
Terminal
Name (Default)
Function (Signal Level)
PI
Master frequency reference pulse train input
(Master frequency reference)
•
Response frequency: 0 Hz to 32 kHz
•
H level duty: 30% to 70%
•
H level voltage: 3.5 V to 13.2 V
•
L level voltage: 0.0 V to 0.8 V
•
Input impedance: 3 kΩ
+10V
Power supply for frequency setting
10.5 V (allowable current 20 mA maximum)
AI1
MFAI1
(Master frequency reference)
Voltage input
•
0 V to 10 V/100% (input impedance: 20 kΩ)
AI2
MFAI2
(Combined to terminal AI1)
Voltage input or current input
Use DIP switch S1 and
H3-09 [AI2 Signal Level Select]
to select the input.
•
0 V to 10 V/100% (input impedance: 20 kΩ)
•
4 mA to 20 mA/100%, 0 mA to 20 mA/100% (input impedance: 250 Ω)
A0V
Frequency reference common
0 V
GND
Connecting shielded cable
-
■
Output Terminals
This chapter contains a list of Output terminals and functions.
Table 3.8 Digital Outputs
Terminal
Name (Default)
Function (Signal Level)
NO
N.O. output
(Fault)
•
Relay output
•
30 Vdc, 10 mA to 1 A
•
250 Vac, 10 mA to 1 A
•
Minimum load: 5 V, 10 mA (Reference value)
NC
N.C. output
(Fault)
CM
Digital output common
Table 3.9 Multi-function Photocoupler Outputs
Terminal
Name (Default)
Function (Signal Level)
DO1
Multi-function photocoupler output 1
(During RUN)
•
Photocoupler output
•
48 V, 2 mA to 50 mA
Note:
Connect a flywheel diode when you drive a reactive load such as a relay coil. Make sure that the diode
rating is larger than the circuit voltage.
O1C
DO2
Multi-function photocoupler output 2
(Speed agree 1)
O2C
Table 3.10 Control Circuit Monitor Output Terminals
Terminal
Name (Default)
Function (Signal Level)
PO
Pulse train output
(Output frequency)
32 kHz (maximum)
Refer to
“
Pulse Train Output
”
for more information.
AO
Analog monitor output
(Output frequency)
Select voltage or current output.
•
0 V to 10 V/0% to 100%
•
4 mA to 20 mA (Receiver recommended impedance: 250 Ω)
Note:
Select using jumper switch S5 and
H4-07 [AO Signal Level Select]
.
A0V
Monitor common
0 V
Summary of Contents for Q2V Series
Page 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Page 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Page 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...