170
SIEPCYEUOQ2V01A Q2V Technical Manual
Model
Terminal
Recommended
Gauge
AWG, kcmil
Applicable Gauge
AWG, kcmil
Wire
Stripping
mm
Terminal Screw
Tightening Torque
N
∙
m (in
∙
lb)
Size
Shape
2030
R/L1, S/L2, T/L3
8
12 - 6
10
M4
1.5 - 1.7
(13.5 - 15)
U/T1, V/T2, W/T3
8
12 - 6
10
M4
1.5 - 1.7
(13.5 - 15)
-, +1, +2
6
12 - 6
10
M4
1.5 - 1.7
(13.5 - 15)
B1, B2
12
12 - 8
10
M4
1.5 - 1.7
(13.5 - 15)
8
10 - 6
-
M5
2.0 - 2.5
(17.7 - 22.1)
2042
R/L1, S/L2, T/L3
6
12 - 6
10
M4
1.5 - 1.7
(13.5 - 15)
U/T1, V/T2, W/T3
6
12 - 6
10
M4
1.5 - 1.7
(13.5 - 15)
-, +1, +2
4
10 - 2
18
M5
•
≤ AWG 10
2.3 - 2.5
(19.8 - 22)
•
AWG 8 ≤
4.1 - 4.5
(36 - 40)
B1, B2
10
14 - 6
10
M4
1.5 - 1.7
(13.5 - 15)
6
10 - 6
-
M5
2.0 - 2.5
(17.7 - 22.1)
2056
R/L1, S/L2, T/L3
4
10 - 2
18
M5
4.1 - 4.5
(36 - 40)
U/T1, V/T2, W/T3
4
10 - 2
18
M5
•
≤ AWG 10
2.3 - 2.5
(19.8 - 22)
•
AWG 8 ≤
4.1 - 4.5
(36 - 40)
-, +1, +2
2
8 - 2
18
M5
4.1 - 4.5
(36 - 40)
B1, B2
8
12 - 6
10
M4
1.5 - 1.7
(13.5 - 15)
6
8 - 4
-
M6
5.4 - 6.0
(47.8 - 53.1)
2070
R/L1, S/L2, T/L3
2
6 - 1
20
M6
5 - 5.5
(45 - 49)
U/T1, V/T2, W/T3
2
8 - 1
20
M6
5 - 5.5
(45 - 49)
-, +1, +2
1
6 - 1/0
20
M6
5 - 5.5
(45 - 49)
B1, B2
8
12 - 6
10
M4
1.5 - 1.7
(13.5 - 15)
4
6 - 4
-
M6
5.4 - 6.0
(47.8 - 53.1)
2082
R/L1, S/L2, T/L3
1
6 - 1/0
20
M6
5 - 5.5
(45 - 49)
U/T1, V/T2, W/T3
2
6 - 1
20
M6
5 - 5.5
(45 - 49)
-, +1, +2
2/0
2 - 2/0
20
M6
5 - 5.5
(45 - 49)
B1, B2
6
10 - 6
10
M4
1.5 - 1.7
(13.5 - 15)
4
6 - 4
-
M6
5.4 - 6.0
(47.8 - 53.1)
*1
Remove insulation from the ends of wires to expose the length of wire shown.
Summary of Contents for Q2V Series
Page 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Page 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Page 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...