11.20 Defaults by Drive Model and Duty Rating ND/HD
SIEPCYEUOQ2V01A Q2V Technical Manual
411
No.
Name
Unit
Default
-
Drive Model
-
2008
2010
2012
2018
C6-01
ND/HD Duty
Selection
-
HD
ND
HD
ND
HD
ND
HD
ND
0
1
0
1
0
1
0
1
o2-04
Drive KVA
Selection
Hex.
64
65
66
67
E2-11
(E4-11, E5-
02)
Motor Rated
Power (kW)
kW
1.1
1.5
1.5
2.2
2.2
3.0
3.0
3.7
L2-04
Powloss
Ramp
Time@recov
ery
s
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
L2-05
UV Detection
Lvl (Uv1)
-
190
190
190
190
190
190
190
190
L3-02
StallP
Level@Accel
%
150
120
150
120
150
120
150
120
L3-06
StallP
Level@Run
%
150
120
150
120
150
120
150
120
L3-24
Acc@Rated
Torque
s
0.142
0.166
0.166
0.145
0.145
0.145
0.145
0.154
L8-02
Overheat Alm
Level
°C
110
110
110
110
110
110
115
115
L8-09
Ground Fault
Selection
-
0
0
0
0
0
0
0
0
n1-03
HuntPrev
Time Constant
ms
10
10
10
10
10
10
10
10
n3-02
HSB CurrLim
Level
1
150
120
150
120
150
120
150
120
n5-02
Mot Inertia
Acceleration
Time
s
0.142
0.166
0.166
0.145
0.145
0.145
0.145
0.154
*1
Parameters within parentheses are for motor 2.
No.
Name
Unit
Default
-
Drive Model
-
2021
2030
2042
2056
C6-01
ND/HD Duty
Selection
-
HD
ND
HD
ND
HD
ND
HD
ND
0
1
0
1
0
1
0
1
o2-04
Drive KVA
Selection
Hex.
68
6A
6B
6D
E2-11
(E4-11, E5-
02)
Motor Rated
Power (kW)
kW
3.7
5.5
5.5
7.5
7.5
11
11
15
b3-04
SpSrch V/F
Gain
%
100
100
100
100
100
100
100
100
b3-06
Speed Curr
Lev1 for
Estimation
-
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
b3-08
Speed ACR
PGain for
Estimation
-
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
b3-26
Dir. Determ.
Level
-
1000
1000
1000
1000
1000
1000
1000
1000
b8-03
eSave Filter
Time
s
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
b8-04
eSave Coef.
Value
-
122.9
94.75
94.75
72.69
72.69
70.44
70.44
63.13
C6-02
Carrier
Frequency
Selection
-
3
7
3
7
3
7
3
7
E2-01
(E4-01)
Mot Rated
Current (FLA)
A
14
19.6
19.6
26.6
26.6
39.7
39.7
53
E2-02
(E4-02)
Mot Rated
Slip
Hz
2.73
1.5
1.5
1.3
1.3
1.7
1.7
1.6
E2-03
(E4-03)
Mot No-Load
Current
A
4.5
5.1
5.1
8
8
11.2
11.2
15.2
Summary of Contents for Q2V Series
Page 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Page 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Page 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...