SIEPCYEUOQ2V01A Q2V Technical Manual
437
Note:
•
You must set
A1-01 = 1 [Access Level = Manual Setup]
to access parameters
A2-01 to A2-32
.
•
When
A1-07 = 1 or 2 [Q2pack Enable = Enable Q2pack or With DI]
, the drive saves
qx-xx [q1-01 to q8-40: Q2pack Parameters]
to
A2-01 to A2-32
.
The drive saves these parameters to
A2-01 to A2-32
.
•
The drive saves a maximum of 32 parameters.
Note:
Set
A1-01 = 2 [Standard Parameters]
or
A1-01 = 3 [Expert Parameters]
to save the necessary parameters.
•
The drive automatically saves changed parameters to
A2-17 to A2-32
.
Note:
Set
A2-33 = 1 [Manual Autoset Parameters = Auto Save]
.
■
A2-33: Manual Autoset Parameters
No.
(Hex.)
Name
Description
Default
(Range)
A2-33
(0126)
Manual Autoset Parameters
Sets the automatic save feature for changes to parameters
A2-17 to A2-32 [MAN2 Param7 to
MAN3 Param12]
.
0
(0, 1)
0 : Manual Entry
Set User Parameters manually.
1 : Auto Save
The drive automatically registers changed parameter
A2-17 to A2-32
. The drive automatically saves the most
recently changed parameter to
A2-17
, and saves a maximum of 16 parameters. After the drive registers 16
parameters, when you save a new parameter, the drive will remove a parameter from the User Parameter list to
make space for the new parameter. The drive removes parameters with First In, First Out.
Use Setup Mode to show the saved parameters.
Note:
In General-Purpose Setup Mode, the drive saves parameters starting with
A2-27
because the drive saves parameters
A2-26
and lower by
default.
◆
Notes for Elevator Applications
When using the drive for elevator applications, read the safety descriptions and precautions, and safely and
correctly use the device.
■
Conditions to Open and Close the Brake
Set
L4-07 = 1 [SpAgree Det.Selection = No Detect@BB]
to open and close the holding brake.
When
L4-07 = 2 [Always Detect]
, the output frequency increases when you input the Run command although the
external baseblock command is input. Because of this, speed detection operates and will open the brake signal.
•
Set Related Parameters
This table shows examples of parameter settings to use the terminal DO2-O2C as the holding brake open and
close signal.
Table 12.3 Holding Brake Open and Close Signal Setting Example
Brake Open and Close Signal
Brake Open and Close Level Adjust
Applicable Control Methods
(A1-02 Settings)
Signal Name
Parameter Settings
Signal Name
Parameter Settings
V/f Control
(0)
OLVector
(2)
Frequency (FOUT) Detection 2
L4-07 = 0
SpAgree Det.Level
L4-01 = 1.0 Hz to 3.0 Hz
x
x
H2-03 = 5
SpAgree Det.Width
L4-02 = 0.0 Hz to 0.5 Hz
*1
When
A1-02 = 2 [OLVector]
, it is the usual setting range. When
A1-02 = 0 [V/f Control]
, set
L4-01
to the rated slip frequency of the
motor + approximately 0.5 Hz. If you set the value too low, motor torque will not be sufficient and it will cause motor rollback. Set
the parameter to agree with these conditions at the same time. If you set the value too high, it will cause overshoot at start.
•
L4-01
>
E1-09 [Min Output Frequency]
•
L4-01
>
L4-02 [Powloss Ramp Time@recovery]
*2
Use
L4-02
to adjust the detection width of Frequency Detection 2. If rollback occurs when the motor stops, change the frequency to
approximately 0.1 Hz.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for Q2V Series
Page 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Page 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Page 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...