534
SIEPCYEUOQ2V01A Q2V Technical Manual
■
E2-09: Motor Mech Loss
No.
(Hex.)
Name
Description
Default
(Range)
E2-09
(0316)
Expert
Motor Mech Loss
Sets the mechanical loss of the motor. It is set as a percentage of
E2-11 [Motor Rated Power
(kW)]
. Usually it is not necessary to change this setting.
0.0%
(0.0 - 10.0%)
Adjust this parameter in these conditions. The drive adds the configured mechanical loss to the torque reference
value as a torque compensation value:
•
There is a large quantity of torque loss from motor bearing friction.
•
There is a large quantity of torque loss in fans and pumps.
■
E2-10: Motor Iron Loss
No.
(Hex.)
Name
Description
Default
(Range)
E2-10
(0317)
Motor Iron Loss
Sets the motor iron loss.
Determined by o2-04, C6-
01
(0 - 65535 W)
■
E2-11: Motor Rated Power (kW)
No.
(Hex.)
Name
Description
Default
(Range)
E2-11
(0318)
Motor Rated Power (kW)
Sets the motor rated output in the units from
o1-58 [Mot Capacity Unit]
.
Determined by o2-04, C6-
01
(0.00 - 650.00 kW)
The drive automatically sets this parameter to the value input for
“
Motor Rated Power
”
during Auto-Tuning.
◆
E3: V/F PARAMETER MOTOR 2
E3 parameters
set the control mode and V/f pattern used for motor 2.
Note:
V/f preset patterns equivalent to those set with
E1-03 [V/f Pattern Selection]
are not available for
E3 parameters
. Use
E3-04 [M2 Max
Out Frequency]
to
E3-10 [M2 Min Out Voltage]
to manually set the V/f pattern.
■
Notes on Manually Setting V/f Patterns
Figure 12.61 Motor 2 V/f Pattern Diagram
•
To configure a linear V/f pattern at frequencies lower than
E3-06 [M2 Base Frequency]
, set
E3-07 = E3-09 [M2
Mid A Frequency = M2 Min Out Frequency]
. In this application, the drive ignores
E1-08 [M2 Mid A Voltage]
.
•
Set the five frequencies as specified by these rules:
E3-09 ≤ E3-07 < E3-06 ≤ E3-11 ≤ E3-04 [M2 Min Out Frequency ≤ M2 Mid A Frequency < M2 Base
Frequency ≤ M2 Mid B Frequency ≤ M2 Max Out Frequency]
Incorrect settings will trigger
oPE10 [V/f Data Setting Error]
.
•
If
E3-11 = 0.0 Hz
, the drive will ignore the V/f pattern settings.
•
When you use
A1-03 [Init Parameters]
to initialize the drive, the drive will reset the manually set values for
E3-
04 to E3-13 [M2 Base Voltage]
to default values.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for Q2V Series
Page 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Page 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Page 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...