548
SIEPCYEUOQ2V01A Q2V Technical Manual
Table 12.32 Specification
Item
Specification
Applicable options
All options that support the Modbus access function (for example, PROFIBUS-DP, PROFINET, EtherNet/IP, EtherCAT)
Compatible Products
Drives that can set F6-16 [Gateway Mode]
Number of connected drives
Maximum: 5 units
Communication specifications
Modbus (RTUmode) communications
Commands/responses
The controller can send this data to each drive (Drive 0 to Drive 4):
•
Control commands: Run commands and frequency references
•
Control responses: Output frequency and drive status (during run, faults)
•
Read and write parameters
•
Read monitors
Synchronous control
Not supported
*1
Gateway Mode is not available with Yaskawa 1000-series drives or previous series drives.
Note:
•
The communication speed in gateway mode is slower than the speed in fieldbus communications. Make sure that the speed is
acceptable for your system.
•
Response speed with the communication option is slower than with point-to-point communications.
•
Set
H5-03 [Mbus Parity]
to the same value on the master drive and slave drives.
WARNING!
Injury to Personnel. Separately prepare safety protection equipment and systems, for example fast stop switches. If
the motor does not stop correctly from the disconnection of communications cable or electrical interference, it can cause serious
injury.
Configuring Gateway Mode
The following table shows sample settings to connect 4 slave drives:
Table 12.33 Sample Settings for Using Gateway Mode
F6-16
[Gateway Mode]
H5-01
[Mbus Address]
H5-02
[Mbus BaudRate]
H5-03
[Mbus Parity]
H5-06
[Mbus Tx Wait
Time]
H5-09
[Mbus CE Detect
Time]
b1-01
[Freq. Ref. Sel. 1]
b1-02
[Run Comm. Sel
1]
Drive 0
(Master Drive)
1 - 4
1F (Default)
5 ms (factory
default)
≥ 2.0 s
3 [Option PCB]
3 [Option PCB]
Drive 1
(Slave drive)
0
5 ms (factory
default)
≥ 0.9 s
2 [Modbus]
2 [Modbus]
Drive 2
(Slave drive)
0
5 ms (factory
default)
≥ 0.9 s
2 [Modbus]
2 [Modbus]
Drive 3
(Slave drive)
0
5 ms (factory
default)
≥ 0.9 s
2 [Modbus]
2 [Modbus]
Drive 4
(Slave drive)
0
5 ms (factory
default)
≥ 0.9 s
2 [Modbus]
2 [Modbus]
*1
Restart the drive to apply the new settings.
*2
Specify the number of slave drives you will connect.
*3
Setting 0 will not let the drive respond to Modbus communications.
*4
Set a slave address that is different from other slave devices.
*5
Enter the same value that you use for the master drive.
*6
To correctly detect the response timeout, do not change the value of H5-06 from the default value.
*7
Set
H5-09 ≥ 0.9
. When
H5-09 < 0.9
, the drive will detect
CE [Modbus Communication Error]
before it detects a response timeout.
*8
On each slave drive, set
b1-01 [Freq. Ref. Sel. 1]
and
b1-02 [Run Comm. Sel 1]
to
2 [Modbus]
.
An Overview of Gateway Mode
When in gateway mode, the drive will operate as shown in
.
A - Controller
B - Communication Option
C - Master Drive (Drive 0)
D - Slave Drives (Drives 1 to 4)
Summary of Contents for Q2V Series
Page 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Page 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Page 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...