SIEPCYEUOQ2V01A Q2V Technical Manual
587
◆
H2: DIGITAL OUTPUTS
H2 parameters
set the MFDO terminal functions.
■
H2-01 to H2-03 Terminal NO/NC-CM, DO1-O1C, DO2-O2C Function Selection
The drive has four MFDO terminals.
shows the default function settings for the terminals.
Table 12.43 MFDO Terminals Default Function Settings
No.
Name
Default
Function
H2-01
NO,NC,CM FuncSelection
3
Fault
H2-02
DO1-O1C Func Selection
5
@Run
H2-03
DO2-O2C Func Selection
F
SpeedAgree1
Refer to
to set
H2-xx [MFDO Function Select]
.
Table 12.44 MFDO Setting Values
Setting Value
Function
Reference
Not Used
1
Drive Ready
2
Drive Enable
3
Fault
4
Alarm
5
@Run
6
@Reverse
7
Zero Speed
B
@FreqOutput
D
LO/RE Status
E
EDM Safety
F
SpeedAgree1
10
USpeedAgree1
11
SpeedAgree2
12
USpeedAgree2
13
FreqDetect 1
14
FreqDetect 2
15
FreqDetect 3
16
FreqDetect 4
17
@Fast Stop
18
@KEBridethru
19
@ShortCBraking
1A
@BaseblockNO
1B
@BaseblockNC
1C
FreqRefSource
1D
RunCmdSource
1E
Motor2 Select
1F
Restart Enable
20
FltReset Active
21
PolePos Detection
22
Ext 24V Supply
Setting Value
Function
Reference
2F
@SpeedSearch
30
@TorqueLimit
32
TrqDetect1NO
33
TrqDetect1NC
37
TrqDetect2NO
38
TrqDetect2NC
39
Timer Output
3C
Comparator 1
3D
Comparator 2
3E
PID Fbk Low
3F
PID Fbk High
4A
DC Bus Undervolt
4B
FreqRef Loss
4C
BrkRes Fault
4D
Motor OL1
4E
Drive PreOH
4F
PreOHTimeLim
60
BrkTransFault
61
BrkTransOH
63
Maintenance
65
WattH Pulse
66
MechWeakDetect
67
ModbusReg 1
69
ModbusReg 2
6A
DataLog Error
90 - 92
Q2pack Digital Output 1 to 3
100 - 192
Inverse output of 0 to 92
Sets an inverse output of the function for
the MFDO. Put a 1 at the front of the
function setting to set inverse output. For
example, set
138
for inverse output of
38
[TrqDetect2NC]
.
*1
Inverse output is not available.
Summary of Contents for Q2V Series
Page 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Page 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Page 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...