622
SIEPCYEUOQ2V01A Q2V Technical Manual
If the drive does not receive data from the master during the time set in
H5-09 [Mbus CE Detect Time]
, it will
detect a
CE
error.
0 : Disabled
Does not detect
CE
. The drive continues operation.
1 : Enabled
Detects
CE
. If the drive detects
CE
, it will operate as specified by the setting of
H5-04 [Mbus Error Stop]
.
■
H5-06: Mbus Tx Wait Time
No.
(Hex.)
Name
Description
Default
(Range)
H5-06
(042A)
Mbus Tx Wait Time
Sets the time to wait to send a response message after the drive receives a command message
from the master.
5 ms
(0 - 65 ms)
Note:
Restart the drive after changing the parameter setting.
Figure 12.99 Drive Transmit Wait Time
■
H5-09: Mbus CE Detect Time
No.
(Hex.)
Name
Description
Default
(Range)
H5-09
(0435)
Mbus CE Detect Time
Sets the detection time for
CE [Modbus Communication Error]
issues when communication
stops.
2.0 s
(0.0 - 25.0 s)
■
H5-10: Mbus 0025H Unit Sel
No.
(Hex.)
Name
Description
Default
(Range)
H5-10
(0436)
Mbus 0025H Unit Sel
Sets the unit of measure used for the Modbus communications monitor register 0025H (output
voltage reference monitor).
0
(0, 1)
0 : 0.1 V units
1 : 1 V units
■
H5-11: Mbus ENTER Command Mode
No.
(Hex.)
Name
Description
Default
(Range)
H5-11
(043C)
RUN
Mbus ENTER Command
Mode
Sets the function to make the Enter command necessary to change parameters through Modbus
communications.
0
(0, 1)
0 : Enter Required
Make all parameter changes then input the Enter command. You must use the Enter command to enable changes
to parameters.
1 : No Enter Required
It is not necessary to input the Enter command to change parameters.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for Q2V Series
Page 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Page 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Page 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...