692
SIEPCYEUOQ2V01A Q2V Technical Manual
0 : Feedback Method
1 : Feedforward Method
■
n8-88: VoutLimSw Level
No.
(Hex.)
Name
Description
Default
(Range)
n8-88
(02BD)
VoutLimSw Level
Sets the current level at which output voltage limit sequence selection occurs as a percentage
where the motor rated current is 100%. Normally there is no need to change this setting.
400%
(0 - 400%)
■
n8-89: VoutLimSwHysteresis
No.
(Hex.)
Name
Description
Default
(Range)
n8-89
(02BE)
VoutLimSwHysteresis
Sets the hysteresis width of the current level at which output voltage limit sequence selection
occurs as a percentage where the motor rated current is 100%. Normally there is no need to
change this setting.
3%
(0 - 400%)
■
n8-90: VoutLimSwSpeed
No.
(Hex.)
Name
Description
Default
(Range)
n8-90
(02BF)
VoutLimSwSpeed
Sets the speed level at which output voltage limit sequence selection occurs as a percentage where
the maximum output frequency is 100%. Usually it is not necessary to change this setting.
200%
(0 - 200%)
■
n8-91: VoutLim Id Limit
No.
(Hex.)
Name
Description
Default
(Range)
n8-91
(02F7)
VoutLim Id Limit
Sets the limit value of feedback output voltage limit Id operation. Enabled when
n8-87 = 0 [O/P
VoltLim Method = Speed Feedback Form]
. Usually it is not necessary to change this setting.
-50%
(-200 - 0%)
■
n8-94: FluxPos Est.Method
No.
(Hex.)
Name
Description
Default
(Range)
n8-94
(012D)
Expert
FluxPos Est.Method
Sets the criteria that the drive uses to find changes in speed or load. Usually it is not necessary to
change this setting.
2
(1, 2)
1 : Softstarter
2 : Speed Feedback
Set
n8-57 = 1 [High-Freq Injection = Enabled]
to enable this parameter. Increases the stability when the speed or
load suddenly change, for example with rapid acceleration/deceleration or impact loads.
■
n8-95: FluxPos Est.Filter Time
No.
(Hex.)
Name
Description
Default
(Range)
n8-95
(012E)
Expert
FluxPos Est.Filter Time
Sets the time constant of the filter used for the recognition criteria value for speed and load
changes. Usually it is not necessary to change this setting.
30 ms
(0 - 100 ms)
Note:
Enabled when
n8-94 = 2 [FluxPos Est.Method = Speed Feedback]
.
◆
nA: PM MOTOR CONTROL TUNING
nA parameters
make adjustments for controlling PM motors.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for Q2V Series
Page 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Page 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Page 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...