The following describes the wiring of PG Option Unit 3G3AX-RX2-PG01.
Switch number
Setting description
1
ON
Encoder A and B phase disconnecting detection enabled
OFF
Encoder A and B phase disconnecting detection disabled
2
ON
Encoder Z phase disconnecting detection enabled
OFF
Encoder Z phase disconnecting detection disabled
3
ON
Do not change the setting
OFF
4
ON
Do not change the setting
OFF
Wiring of PG Option Unit
AP, AN / BP, BN
ZP, ZN
EAP, EAN
EBP, EBN
EZP, EZN
EP12×2
EG
3G3AX-RX2-PG01
EP5×2
FG
Max.
250mA
ZN
Max.200kp/s
SAP
RSA
SAN
150 Ω
150 Ω
SAN
SBP
RSB
SBN
SBN
EG
Line-driver output
encoder
A,B,Z-phase pulse
Pulse velocity
200 kp/s max.
Wiring length 20 m max.
RS422 compliant
receiver
RS422 compliant
driver
Terminating
resistor
When short-circuited,
terminating resistor
enabled
Wiring length 20 m max.
When short-circuited,
terminating resistor
enabled
Terminating
resistor
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......