3 - 19
3 Operation
High-function General-purpose Inverter RX2 Series User’s Manual
3-2 Param
eter Sett
ing
s
3
3-
2-2 C
oncu
rren
t Monito
r Mode
Example1) Change the [AA101] First main speed command selection to [Ai1] terminal.
The [Ai1] terminal is an analog input terminal (voltage/current).
Set-up procedure
Action
Press the Enter key while [AA101] is displayed.
(Tips)
The information currently selected is shown in the lower sec-
tion. “07: Parameter setting” is currently selected.
Using the up and down (
) keys, select “01 [Ai1]
terminal”, and then press the F2(2) key.
(Tips)
Data is saved when the F2(2) key is pressed. It is still saved
even after the device is turned off.
When configuring an item, the entire screen changes to the
screen for setting the item.
To confirm if the data is correctly changed, check the lower
section. Press the F1(1) key to return to the monitor.
(Tips)
The information currently selected is shown in the lower sec-
tion.
“01 [Ai1] terminal” is currently selected.
Output Frequency
0.00 Hz
AA101
First main speed command selection
07: Parameter set-up
AA101
First main speed command selection
01 [Ai1] terminal
02 [Ai2] terminal
03 [Ai3] terminal
Output Frequency
0.00 Hz
AA101
First main speed command selection
01: [Ai1] terminal
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......