(b) SM (PMM) control parameter
Display condition: AA121 > 10 or AA221 > 10
(c) Position control parameter
Display condition: AA123 ≠ 00 or AA223 ≠ 00
HC*20
* time constant for torque current command filter
HC*21
* speed feed forward compensation adjustment gain
Parameter
Name
Hd*02
* SM(PMM) motor capacity selection
Hd*03
* SM(PMM) motor poles selection
Hd*04
* SM(PMM) base frequency
Hd*05
* SM(PMM) maximum frequency
Hd*06
* SM(PMM) motor rated voltage
Hd*08
* SM(PMM) motor rated voltage
Hd*10
* SM(PMM) motor constant R
Hd*12
* SM(PMM) motor constant Ld
Hd*14
* SM(PMM) motor constant Lq
Hd*16
* SM(PMM) motor constant Ke
Hd*18
* SM(PMM) motor constant J
Hd*30
* SM(PMM) lowest frequency (switch) (SM-SLV, SM-IVMS)
Hd*31
* SM no-load current (SM-SLV, SM-IVMS)
Hd*32
* SM start method selection (SM-SLV, SM-IVMS, SM-CLV)
Hd*33
* SM initial position estimation Zero-V stand-by times (SM-SLV, SM-IVMS, SM-CLV)
Hd*34
* SM initial position estimation Detection stand-by times (SM-SLV, SM-IVMS, SM-CLV)
Hd*35
* SM initial position estimation Detection times (SM-SLV, SM-IVMS, SM-CLV)
Hd*36
* SM initial position estimation Voltage gain (SM-SLV, SM-IVMS, SM-CLV)
Hd*37
* SM initial position estimation Magnetic-pole position offset
Hd-41
IVMS carrier frequency
Hd-42
Filter gain of IVMS detection current
Hd-43
Open-phase voltage detection gain selection SM(PMM)-IVMS
Hd-44
Selection of open-phase switch threshold correction SM(PMM)-IVMS
Hd-45
Speed control P gain SM(PMM)-IVMS
Hd-46
Speed control I gain SM(PMM)-IVMS
Hd-47
Waiting time for open-phase switching SM(PMM)-IVMS
Hd-48
Restriction on the rotation-direction determination SM(PMM)-IVMS
Hd-49
Timing adjustment for open-phase voltage detection SM(PMM)-IVMS
Hd-50
Minimum pulse range adjustment SM(PMM)-IVMS
Hd-51
Current limit of IVMS threshold
Hd-52
IVMS threshold gain
Hd-58
IVMS carrier-frequency switching start/finish point
Parameter
Name
AE-01
Electronic gear installation position selection
AE-02
Numerator of electronic gear ratio
AE-03
Denominator of electronic gear ratio
AE-04
Positioning completion range setting
AE-05
Positioning completion delay time setting
AE-06
Positioning control feed forward
AE-07
Position loop gain
Parameter
Name
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......