5 - 3
5 Monitor
High-function General-purpose Inverter RX2 Series User’s Manual
5-1 F
re
que
ncy Mo
nito
r
5
5-
1-1 Output F
reque
ncy Monitor
5-1
Frequency Monitor
Displays the output frequency of an inverter.
Output frequency monitor adjusts frequency command according to the setting of the accelera-
tion/deceleration time after the inverter starts operation.
Parameter
5-1-1
Output Frequency Monitor
Item
Parameter
Data
Description
Output frequency
monitor
[dA-01]
0.00 to 590.00 (Hz)
Displays output frequency.
Output frequency
monitor (with sign)
[dA-12]
-590.00 to 590.00 (Hz)
Displays output frequency with sign.
A forward revolution is indicated with +
sign, and a reverse revolution with -.
ON
0
Time (sec)
Output frequency
monitor [dA-01]
Frequency (Hz)
Frequency command
after calculation
[dA-04]
Operation command