5-12 Braking Resistor Load Ratio Monitor
Display the use rate of braking resistor circuit (BRD).
Precautions for Correct Use
• A setting is required for a braking resistor circuit (BRD) to operate.
For details, see
8-2-5 Regenerative Braking Function
• The breaking resistor overload error [E006] is generated when the displayed rate exceeds
the Dynamic brake usage rate [bA-60].
Parameter
Item
Parameter
Data
Description
BRD load factor monitor
[dA-41]
0.00 to 100.00 (%)
Displays the load ratio of braking resis-
tor.
Dynamic brake usage rate
[bA-60]
0.0 to 100.0 (%)
Sets the maximum use rate of braking
resistor.