5 - 23
5 Monitor
High-function General-purpose Inverter RX2 Series User’s Manual
5-13 Inv
erter Status Mo
nito
r
5
Detailed Monitor for Icon 2 RETRY [dC-39]
Detailed Monitor for Icon 2 NRDY [dC-40]
Data
Status
Description
01
Waiting to retry after a trip.
Retry Standby.
02
Waiting to restart.
Waiting to restart.
00
A state other than those above.
A state other than those above.
Data
Status
Description
01
Tripped.
A trip has occurred.
02
Power supply abnormality.
Power failure or undervoltage state.
03
Being reset.
Being reset or waiting to cancel reset.
04
STO
STO is enabled.
05
Waiting.
Waiting for inverter’s internal circuit or internal condition to be
stable.
06
Data inconsistency.
A setting inconsistency exists (warning).
07
Sequence abnormality.
Abnormality during a sequence operation.
08
Free-run.
Free-run is enabled (free-run operation).
09
Forced stop state.
Operation command isn’t permitted. Or forced stop is being
issued. (Deceleration stop behavior)
00
A state other than those above.
A state other than those above.
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......