6 Basic Parameter Settings
6 - 18
High-function General-purpose Inverter RX2 Series User’s Manual
Use IVMS control when a high torque is required for activation while you use SM/PMM motors.
Precautions for Correct Use
• If a high torque is necessary for activation, original IVMS control is used. If 03 is chosen for
the auto-tuning selection [HA-01], it can be detected whether the target motor can be driven
with the IVMS control, although combination check should be made in advance.
• The tuning with the IVMS control should be performed on an independent motor with the
Control mode selection, 1st-motor [AA121] set to 12 (SM/PMM: IVMS activation).
• In case of failure of the auto-tuning with the IVMS control, data necessary for the IVMS con-
trol cannot be obtained from the motor and the Control mode selection, 1st-motor [AA121]
should be set to 11 (SM/PMM: Synchronous activation) to drive the motor.
IVMS Auto-tuning
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......