A frequency command is given by input from the terminal block.
The inverter has three kinds of external analog input terminals.
For each input, relation between the input signal and the frequency command can be set inde-
pendently.
To add/subtract a command, the sub frequency input source selection, 1st-motor [AA102] and Calcula-
tion symbol selection for Speed reference, 1st-motor [AA105] should also be set. [Ai3] can be added to
[Ai1] and [Ai2] without choosing an operator in the [Cb-22][Ai3] terminal selection. For details, see
Precautions for Correct Use
• The output of the inverter requires not only a frequency command but also an operation com-
mand.
• Note that the voltage input and the current input are switched from each other by the terminal
block switch.
• For adjustment of the analog input, see
Item
Parameters
Data
Description
Default
data
Main speed input
source selection,
1st-motor
[AA101]
07
The frequency set from the LCD operator is for
main speed
In this case the setting is made for [Ab110].
01
*1
*1. Default data when default data select
i
on (UB-02) is set to 01.
Sub frequency input
source selection,
1st-motor
[AA102]
07
Auxiliary speed to use switching and arithmetic
functions is set from the LCD operator. For aux-
iliary speed, the setting is made for [AA104].
Multispeed-0 setting,
1st-motor
[Ab110]
0.00 to
590.00(Hz)
Frequency setting of the main speed on the
LCD operator.
Shared for the 0th speed of the multi-step speed
function.
00
Sub speed setting,
1st-motor
[AA104]
0.00 to
590.00(Hz)
Frequency setting of the auxiliary speed on the
LCD operator.
0.00
RUN-key Direction of
LCD operator,
1st-motor
[AA-12]
00
Forward rotation operation
00
01
Reverse rotation operation
Output terminal func-
tion
[CC-01] to
[CC-07]
010
[FREF] ON when a frequency command can be
given from the LCD operator.
-
6-4-3
Case where Command Is Given from Terminal Block Analog
Signals
Terminal connection
Input range
Switching method
Ai1-L
0 to 10 V/0 to 20 mA switchable
SW1 on the board is switched.
Ai2-L
0 to 10 V/0 to 20 mA switchable
SW2 on the board is switched.
Ai3-L
-10 to 10 V
-
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......