6 Basic Parameter Settings
6 - 40
High-function General-purpose Inverter RX2 Series User’s Manual
Action Table
Action Chart
Ex.) 2nd speed is effective.
In this case we have [CA-06]=007 (SF1) and [CA-07]=008 (SF2).
No assignment is made for 009 (SF3) and 013 (SF7).
Only the input terminal No. 7 (SF2) is ON.
If SF1 becomes ON in this state, the 1st speed becomes effective.
Multi-step
speed
SF7
SF6
SF5
SF4
SF3
SF2
SF1
Parameters
0th speed
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Ab110
1st speed
-
-
-
-
-
-
ON
Ab-11
2nd speed
-
-
-
-
-
ON
OFF
Ab-12
3rd speed
-
-
-
-
ON
OFF
OFF
Ab-13
4th speed
-
-
-
ON
OFF
OFF
OFF
Ab-14
5th speed
-
-
ON
OFF
OFF
OFF
OFF
Ab-15
6th speed
-
ON
OFF
OFF
OFF
OFF
OFF
Ab-16
7th speed
ON
OFF
OFF
OFF
OFF
OFF
OFF
Ab-17
SF1
SF2
SF3
SF4
SF5
FW
SF6
SF7
7th speed
6th speed
4th speed
3rd speed
2nd speed
1st speed
0th speed
Frequency command from the
place selected for the frequency
command
1st speed
5th speed
S
SF
F4
S
SF
F3
S
SF
F2
S
SF
F1
-
-
-
ON
-
-
ON
OFF
-
ON
OFF
OFF
5
6
[SF1]
7
[SF2]
COM
Multi-step
speed
Input terminal
1st speed
2nd speed
3rd speed
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......