6 - 43
6 Basic Parameter Settings
High-function General-purpose Inverter RX2 Series User’s Manual
6-4 F
requ
ency C
o
mm
and
Sett
ing
s
6
6-
4-13
Temporal Chang
e of Fr
equency C
ommand Destinations
A frequency command uses [AHD] in the analog input.
Parameter
When [F-OP] terminal is ON, the frequency destination can be changed temporally.
When 023 [F-OP] terminal is ON, the command destination of [CA-70] is employed in a priority to the
frequency command destination given in [AA101].
Precautions for Correct Use
When 023 [F-OP] terminal is ON, the operation command destination also employs the opera-
tion command selection designated in [CA-71].
Parameter
Item
Parameters
Data
Description
Main speed command
selection
[AA101]
01 to 15
01: Ai1-L input, 02: Ai2-L input, 03: Ai3-L input
Input terminal function
selection
[CA-01] to
[CA-11]
019
AHD: Analog command holding
6-4-13 Temporal Change of Frequency Command Destinations
Item
Parameters
Data
Description
Default
data
Input terminal function
selection
[CA-01] to
[CA-11]
023
[F-OP]: Gives a forced command.
-
Speed reference
source selection at
[F-OP] is active
[CA-70]
01 to 15
01: Ai1-L input, 02: Ai2-L input, 03: Ai3-L input,
04: (Reserved), 05: (Reserved), 06: (Reserved),
07: parameter setting,
08: RS485 communication, 09:option 1,
10: option 2, 11: option 3,
12: pulse string input (main body),
13: pulse string input (option)
14: program function, 15: PID arithmetic
01
RUN command source
selection at [F-OP] is
active
[CA-71]
00 to 06
00: [FW]/[RV] terminal, 01: 3 wire,
02: RUN key on LCD operator,
03: RS485 communication, 04: option 1,
05: option 2, 06: option 3
00
AHD
ON
ON
Analog input
Frequency command
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......