6 - 63
6 Basic Parameter Settings
High-function General-purpose Inverter RX2 Series User’s Manual
6-
7
Acc
eleratio
n/Dece
leration
Sett
ing
s
6
6-
7-3 Switching
of
A
cceler
atio
n or Deceleration
T
ime with Mult
i-
Speed Step
Example (1) If the multi-speed 3rd speed is engaged and the revolution is accelerating, the enabled
acceleration time is the acceleration time setting for Multispeed-3 [AC-38].
Example (2) If the multi-speed 1st speed is engaged and the revolution is decelerating, the enabled
deceleration time is the deceleration time setting for Multispeed-3 [AC-40] for the multi-speed 3rd
speed that has been engaged until the multi-speed 1st speed is engaged.
Exemplar Operation
FW
[AC-30] [AC-34] [AC-38] [AC-40] [AC-42]
[AC-40]
[AC-42] [AC-44]
If the set frequency is the same, only the acceleration or
deceleration time can be changed.
3rd speed [Ab-13], 4th speed [Ab-14]
2nd speed [Ab-12]
1st speed [Ab-11]
Output
frequency
Acceleration or
deceleration
time
Multiple
speeds
1st speed
2nd speed 3rd speed
3rd speed
2nd speed 4th speed
1st speed
4th speed
1st speed
acceleration
2nd speed
acceleration
3rd speed
acceleration
3rd speed
deceleration
4th speed
acceleration
Command
unchanged
3rd speed
deceleration
4th speed
acceleration
4th speed
deceleration
Example (1)
Example (2)
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...