7 - 13
7 Advanced Settings
High-function General-purpose Inverter RX2 Series User’s Manual
7-2 Sele
ction
of Motor Co
ntro
l Meth
o
d
s
7
7-2
-6
A
utomatic
Torque Boost
Parameter
Item
Parameter
Data
Description
Default
data
Control mode
[AA121]
03
To use the automatic torque boost (IM).
00
Stability constant
[HA110]
0 to 1000(%)
To adjust the control for reducing the hunting of
motors.
100
Async.Motor Base
frequency setting,
1st-motor
[Hb104]
10.00 to the
maximum fre-
quency (Hz)
To set the base frequency of motors.
50
*1
*1. Default data when default data selection (UB-02) is set to 01.
Async.Motor Maxi-
mum frequency
setting, 1st-motor
[Hb105]
Base fre-
quency to
590.00 (Hz)
To set the maximum frequency of motors.
50
*1
Async.Motor rated
voltage, 1st-motor
[Hb106]
1 to 1000 (V)
Set the rated voltage of motors.
200V:
230
*1
400V:
400
*1
Automatic torque
boost voltage com-
pensation gain,
1st-motor
[HC101]
0 to 255
To adjust the amount of the voltage added by
the automatic torque boost.
100
Automatic torque
boost slip compen-
sation gain,
1st-motor
[HC102]
0 to 255
To adjust the amount of the frequency added by
the automatic torque boost.
100
Phenomenon
Estimated cause(s)
Exemplar measures to be taken
Slower motor revolu-
tion at low speeds than
what is expected
Insufficient output volt-
age, which in turn ren-
ders the torque
insufficient
Make an adjustment by incrementing the automatic torque
boost voltage compensation gain [HC101] by approximately
5% each time.
Insufficient frequency
correction, which in
turn renders the torque
insufficient.
Make an adjustment by incrementing the automatic torque
boost slip compensation gain [HC102] by approximately 5%
each time
A heavy load lowers
the revolution fre-
quency of the motor.
Insufficient frequency
correction, which in
turn renders the torque
insufficient.
Make an adjustment by incrementing the automatic torque
boost slip compensation gain [HC102] by approximately 5%
each time
A heavy load raises
the revolution fre-
quency of the motor.
An excessive fre-
quency correction
raises the frequency.
Make an adjustment by decrementing the automatic torque
boost slip compensation gain [HC102] by approximately 5%
each time
With a heavy load, an
acceleration causes
an over current.
An excessive voltage
correction increases
the current.
Make an adjustment by decrementing the automatic torque
boost voltage compensation gain [HC101] by approximately
5% each time.
An excessive fre-
quency correction
raises the frequency.
Make an adjustment by decrementing the automatic torque
boost slip compensation gain [HC102] by approximately 5%
each time
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......