7 - 27
7 Advanced Settings
High-function General-purpose Inverter RX2 Series User’s Manual
7-2 Sele
ction
of Motor Co
ntro
l Meth
o
d
s
7
7-2
-1
1 Synchronous Motor
(Per
m
anent Magnet
Motor)
Contro
l
Precautions for Correct Use
• Some SM (PMM) may be unable to start in the IVMS start mode.
• For IVMS control mode, you are required to make a precise adjustment. By using the
auto-tuning selection[AH-01]=03, check that the target motor can be operated by IVMS con-
trol. If the auto-tuning result is NG, you need to find other control modes because the target
motor cannot be operated by IVMS control.
• IVMS start mode requires a re-adjustment when the inverter is replaced. When a malfunc-
tioning inverter needs to be restored immediately by replacing the malfunctioning inverter
with a new one, the synchronous starting mode should be used.
• As the IVMS start mode is a very special control, which may make a unique operation sound
as the starting sound.
Parameters for IVMS Start Mode
Item
Parameter
Data
Description
Default
data
Carrier frequency
at IVMS
[Hd-41]
0.5 to
16.0(kHz)
Set the carrier frequency during the IVMS drive.
Usually, the value does not require to change.
2.00
Filter gain of cur-
rent detection at
IVMS
[Hd-42]
0 to 1000
The filter adjustment gain applied to the detec-
tion current during the IVMS drive.
100
Open phase volt-
age detection gain
[Hd-43]
00 to 04
The adjustment gain applied to the detection
voltage during the IVMS drivel.
00
Open phase
switching thresh-
old compensation
[Hd-44]
00
IVMS correction: Disabled (no correction)
01
01
IVMS correction: Enabled (correction to be con-
ducted)
P-Gain for speed
control,
SM(PMM)-IVMS
[Hd-45]
0 to 1000
Speed control P gain during the IVMS drive A
larger value enhances the responsiveness of
the speed control.
100
I-Gain for speed
control,
SM(PMM)-IVMS
[Hd-46]
0 to 10000
Speed control I gain during the IVMS drive A
larger value enhances the responsiveness of
the speed control.
100
Wait time for open
phase switching,
SM(PMM)-IVMS
[Hd-47]
0 to 1000
Waiting time for the open-phase switching
during the IVMS drive. A larger value enhances
the stability.
15
Limitation of deci-
sion about the
drive direction,
SM(PMM)-IVMS
[Hd-48]
00
Rotation-direction determination: Disabled (no
restriction)
01
01
Rotation-direction determination: Enabled
(restricted to the operation-command direction)
Open phase volt-
age detection tim-
ing adjustment,
SM(PMM)-IVMS
[Hd-49]
0 to 1000
Adjustment value of the IVMS detection timing.
Usually, the value does not require to change.
10
Minimum pulse
width adjustment,
SM(PMM)-IVMS
[Hd-50]
0 to 1000
To adjust the width of the voltage pulse during
the IVMS drive. A larger value renders the pulse
width wider.
100
IVMS Current Limit
for threshold
[Hd-51]
0 to 255
Set a limit on each of the upper and the lower
limits of the detection current during the IVMS
drive.
Enabled when [Hd-44] = 01 (enabled).
100
IVMS Threshold
Gain
[Hd-52]
0 to 255
To adjust the IVMS auto-tuning value.
100
IVMS Carrier fre-
quency start/end
point
[Hd-58]
0 to 50(%)
To adjust the point where the carrier frequency
is switched in the IVMS start mode. Usually, the
value does not require to change.
5
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......