8 - 101
8 Applied Settings
High-function General-purpose Inverter RX2 Series User’s Manual
8
-4 Co
n
tr
o
l Fu
n
ction
8
8-4
-7 Pulse
T
rain Position Contr
ol
For more information about the pulse train input mode, refer to the following.
1. MD0: 90° phase difference pulse train
2. MD1: Forward/reverse rotation c pulse train
3. MD2: Forward rotation pulse train + reverse rotation pulse train
Input Mode for the Pulse Train Position Control
SAP
SAN
SBP
SBN
(Pulse train input)
(Pulse train input)
Detection
Number of
pulses
Forward rotation
Reverse
rotation
Time
SAP
SAN
SBP
SBN
(Pulse train input)
(Forward/reverse rotation command)
Forward rotation
Reverse
rotation
Time
Detection
Number of
pulses
SAP
SAN
SBP
SBN
(Forward rotation pulse train input)
(Reverse rotation pulse train input)
Forward
rotation
Reverse
rotation
Time
Detection
Number of
pulses
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......