8 Applied Settings
8 - 106
High-function General-purpose Inverter RX2 Series User’s Manual
(4) When the [AE-05] positioning completion delay time passes after the remaining number of pulses
enters the [AE-04] positioning completion range setting, the [POK] signal is output.
(The output continues until the ORT terminal is turned off.)
After the positioning completes, the servo lock status continues until the operation command is
turned off.
Parameter
Item
Function
Code
Data/
Data Range
Description
Default
data
Control mode
selection, 1st-motor
[AA121]
10
Vector control with sensor
00
Vector control mode
selection, 1st-motor
[AA123]
00
Speed/Torque control mode
00
01
Pulse train position control mode
Pulse train detection
object selection
[CA-90]
00
Disabled
00
01
Pulse train frequency command
02
Speed feedback
03
Pulse count
Encoder constant set-
ting
[CA-81]
32 to 65535
Setting of the number of pulses.
1024
Encoder position
selection
[CA-82]
00
A phase precedes
00
01
B phase precedes
Encoder constant set-
ting
[ob-01]
32 to 65535
Setting of the number of pulses.
1024
Encoder position
selection
[ob-02]
00
A phase precedes
00
01
B phase precedes
Stop position selection
of Home search func-
tion
[AE-10]
00
Parameter setting
00
01
Option 1
02
Option 2
03
Option 3
Stop position of Home
search function
[AE-11]
0 to 4095
Note 2)
0
Speed reference of
Home search function
[AE-12]
0.00 to
120.00(Hz)
Note 1)
0.00
Direction of Home
search function
[AE-13]
00
Forward rotation
00
01
Reverse rotation
Positioning complete
range setting
[AE-04]
0 to 10000(pls)
Set the value equivalent to encoder 4 multi-
plication
5
Positioning complete
delay time setting
[AE-05]
0.00 to 10.00(s)
Set the time from the positioning completion
to the output of the [POK] signal.
0.00
Position feed-forward
gain setting
[AE-06]
0 to 655.35
Position feed forward gain.
0.00
Position loop gain set-
ting
[AE-07]
0.00 to
100.00(rad/s)
Position loop gain.
0.50
Input terminal
[CA-01] to
[CA-11]
069
ORT: Orientation
-
109
PLZ: Pulse train input Z
Output terminal
[CC-01] to
[CA-06]
043
POK: Positioning completion
-
Relay output terminal
[CA-07]
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......