8 - 119
8 Applied Settings
High-function General-purpose Inverter RX2 Series User’s Manual
8
-4 Co
n
tr
o
l Fu
n
ction
8
8-4
-9
A
bsolute Position C
ontrol
Zero Return Related Parameters
Item
Function
Code
Data/
Data Range
Description
Default
data
Homing function
selection
[AE-70]
00
Low speed zero return
00
01
High speed zero return 1
02
High speed zero return 2
Direction of homing
function
[AE-71]
00
Forward rotation
00
01
Reverse rotation
Low-speed of homing
function
[AE-72]
0.00 to
10.00(Hz)
Speed in the low speed zero return mode.
0.00
High-Speed of homing
function
[AE-73]
0.00 to
590.00(Hz)
Speed in the high speed zero return mode.
0.00
Input terminal function
[CA-01] to
[CA-11]
072
PCLR: Position deviation clear
-
076
CP1: Position command selection 1
077
CP2: Position command selection 2
078
CP3: Position command selection 3
079
CP4: Position command selection 4
080
ORL: Origin limit signal
081
ORG: Zero return start signal
082
FOT: Forward rotation drive stop
083
ROT: Reverse rotation drive stop
084
SPD: Speed/position switching
085
PSET: Position data preset
110
TCH: Teaching
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......