8 Applied Settings
High-function General-purpose Inverter RX2 Series User’s Manual
8
-4 Co
n
tr
o
l Fu
n
ction
8
8-4
-10 Ser
vo Lo
ck (SON)
Parameter
Precautions for Correct Use
• If the torque at the time of start is insufficient, it may be improved by adjusting the starting
boost amount [HC111][HC112] or speed response [HA115].
Refer to
7-2 Selection of Motor Control Methods
• If the torque at the time of start is insufficient, it may be improved by using the torque bias
function.
Refer to
Item
Parameter
Data
Description
Default
data
Input terminal function
[CA-01] to
[CA-11]
054
Servo lock function [SON]
-
STOP mode selection,
1st-motor
[AA115]
00
Perform the deceleration stop when the
operation command is off.
00
01
Perform the free-running when the operation
command is off.
Restart mode after
FRS release
[bb-40]
00
Perform the 0 Hz restart.
00
01
Perform the frequency matching restart.
*1
*1. Refer to
7-5-3 Frequency Matching Start
02
Perform the frequency pull-in restart.
*2
*2. Refer to
03
XXXXXX
Retry wait time before
motor restart
[bb-26]
0.3 to 100.0(s)
Set the waiting time after an operation com-
mand.
0.3
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......