8 Applied Settings
8 - 124
High-function General-purpose Inverter RX2 Series User’s Manual
The operations of 16C are as follows.
The specifications of the relay contact 16C are as follows.
Parameter
Contact a:
The contact closes when the functional operation is ON and opens when OFF.
Contact b:
The contact closes when the functional operation is OFF and opens when ON.
Relay Output 16C
[CC-16]
Control power
Functional operation
Output terminal state
00
On
ON
Close
OFF
Open
Off
-
Open
01
On
ON
Open
OFF
Close
Off
-
Open
Resistive load
Inductive load
16C
Maximum contact capacity
AC250V,2A
AC250V,1A
Minimum contact capacity
AC250V,1mA
Item
Parameter
Data
Description
Output terminal func-
tion selection 11-15
[CC-01] to
[CC-05]
017
An alarm signal is output to the output terminal to
which 017 [AL] has been assigned.
ON: When an alarm has occurred
OFF: When no alarm has occurred
Relay output terminal
function selection
16A-16C
[CC-06]
Relay output terminal
function selection
AL1-AL0/AL2-AL0
[CC-07]
Output terminal func-
tion selection
[CC-11] to
[CC-15]
00
Operates as contact a (NO).
01
Operates as contact b (NC).
1a relay output termi-
nal function selection
a/b (NO/NC) selection
[CC-16]
00
Operates as contact a (NO).
01
Operates as contact b (NC).
1c relay output termi-
nal function selection
a/b (NO/NC) selection
[CC-17]
00
See the table at the upper left.
01
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......