8 Applied Settings
8 - 140
High-function General-purpose Inverter RX2 Series User’s Manual
8-7
Terminal Output During Run
This signal is output while an inverter operates.
Assign the output terminal function 001 [RUN] running signal to one of [CC-01] to [CC-07] that corre-
sponds to the output terminal and output the signal.
The timing chart is as follows.
Run signal is output until a motor stops even if the operation command (FW) is OFF.
Precautions for Correct Use
• The signal becomes ON not only when the motor is operating at normal rotation but also
when a voltage is output to the motor as a function such as DC breaking.
• The signal [RUN] will not be output when the inverter is waiting for a retry or DC breaking.
Parameter
8-7-1
Signal during RUN (RUN)
Item
Parameter
Data
Description
Output terminal func-
tion selection 11-15
[CC-01] to
[CC-05]
001
The signal [RUN] is output to the output terminal
assigned.
Relay output terminal
function selection
16A-16C
[CC-06]
Relay output terminal
function selection
AL1-AL0/AL2-AL0
[CC-07]
Output frequency
Operation
command [FW]
Output signal [RUN]
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......