8 - 151
8 Applied Settings
High-function General-purpose Inverter RX2 Series User’s Manual
8-
9
Ap
p
lied
Outp
ut
8
8-9
-2 Logical Output Signal
• When the analog input becomes the maximum value (Max) because of a short circuit in the input wire
You can combine the operation of the output terminal function to perform a logical operation for output
signals in the inverter to output various signals.
You can select three types of operators: AND, OR, and XOR.
Precautions for Correct Use
All output signals are subject to operation. However, you are not able to include the results of
logical operations [LOG1] to [LOG7] into the targets of arithmetic operation.
8-9-2
Logical Output Signal
Selected signal
Arithmetic operation
target 1 selection
Arithmetic operation
target 2 selection
Operator selection
068: Logical output signal 1 (LOG1)
[CC-40]
[CC-41]
[CC-42]
069: Logical output signal 2 (LOG2)
[CC-43]
[CC-44]
[CC-45]
070: Logical output signal 3 (LOG3)
[CC-46]
[CC-47]
[CC-48]
071: Logical output signal 4 (LOG4)
[CC-49]
[CC-50]
[CC-51]
072: Logical output signal 5 (LOG5)
[CC-52]
[CC-53]
[CC-54]
073: Logical output signal 6 (LOG6)
[CC-55]
[CC-56]
[CC-57]
074: Logical output signal 7 (LOG7)
[CC-58]
[CC-59]
[CC-60]
Max(100%)
Min(Ai1/Ai2:0%)
(Ai3 :-100%)
[CE-50]/[CE-52]/[CE-54]
[CE-40]/[CE-43]/[CE-46]
[CE-41]/[CE-44]/[CE-47]
[CE-42]/[CE-45]/
[CE-48]
[WCAi1]/[WCAi2]/
[WCAi3]
[Ai1Dc]/[Ai2Dc]/
[Ai3Dc]
Window comparator
upper limit level
Analog input value
Analog operation level
in abnormal conditions
Ai1/Ai2/Ai3 inputs
Hysteresis width
A short circuit
occurred↓
Analog adopted value
Window comparator
lower limit level
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......