8 - 153
8 Applied Settings
High-function General-purpose Inverter RX2 Series User’s Manual
8-
9
Ap
p
lied
Outp
ut
8
8-9
-2 Logical Output Signal
Parameter
Item
Parameter
Data
Description
Output terminal func-
tion selection
Relay output terminal
function selection
[CC-01] to [CC-05]
062
063
064
065
066
067
068
LOG1: Result of logical operation 1
LOG2: Result of logical operation 2
LOG3: Result of logical operation 3
LOG4: Result of logical operation 4
LOG5: Result of logical operation 5
LOG6: Result of logical operation 6
LOG7: Result of logical operation 7
16C relay output termi-
nal function selection
[CC-06]
AL relay output termi-
nal function selection
[CC-07]
Logical output signal
selection 1
[CC-40], [CC-43], [CC-46],
[CC-49], [CC-52], [CC-55],
[CC-58]
Select from the out-
put terminal function
selection data
(excluding LOG1 to
LOG7)
Select Arithmetic operation target 1
Logical output signal
selection 2
[CC-41], [CC-44], [CC-47],
[CC-50], [CC-53], [CC-56],
[CC-59]
Select from the out-
put terminal function
selection data
(excluding LOG1 to
LOG7)
Select Arithmetic operation target 2
Logical output signal
operator selection
[CC-42], [CC-45], [CC-48],
[CC-51], [CC-54], [CC-57],
[CC-60]
00
AND
01
OR
02
XOR
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......