(Ex.4) Invalidating resetting at normal ([CA-72]=02,03)
(Ex.5) When frequency adjustment restarting is selected ([bb-41]=01)
In the “Reset restarting selection [bb-41],” selecting “01 (frequency adjustment restarting)” allows you to
perform the frequency adjustment restarting when turning on the power supply again. When “00
(Restarting with 0 Hz)” is set, the operation starts from 0 Hz without waiting for the “Retry stand-by time
for instantaneous power failure and insufficient voltage [bb-26].”
Precautions for Correct Use
Even when the frequency adjustment restarting is selected, the “Restarting with 0 Hz” occurs in
the cases shown below.
• When an output frequency is 1/2 of a base frequency or below
• When the induced voltage of the motor quickly attenuates
• When the “Lower limit setting for frequency adjustment [bb-42]” is set, and a frequency equal
to or below this set frequency is detected
Examples of Restarting When Resetting
Output
frequency
Operation
instruction
RS input
Resetting is invalidated during operation.
ON
OFF
ON
ON
Power
supply
FW input
Motor
Frequency
Free running
Frequency
adjustment
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......