8 Applied Settings
8 - 176
High-function General-purpose Inverter RX2 Series User’s Manual
The specifications of Output terminals 11 to 15 are as shown below. The same specifications are
applied.
The open collector output operation is as shown below.
The specifications of Relay 1a output terminals 16A to 16C are as shown below.
The operations of 16A to 16C are as shown below.
Open Collector Output Terminals
Electrical characteristics
Terminals (11 to 15)-CM2
Voltage drop at ON: 4 V or below
Allowable maximum voltage: DC 27 V
Allowable maximum current: 50 mA
[CC-11] to [CC-15]
Control power supply
Output of inverter function
Open collector operation
00
(Contact a)
On
ON
Close
OFF
Open
Off
-
-
01
(Contact b)
On
ON
Open
OFF
Close
Off
-
-
Relay 1a Output Terminals
Electrical characteristics
16A-16C
Voltage drop at ON: 4 V or below
Allowable maximum voltage: DC 27 V
Allowable maximum current: 50 mA
[CC-16]
Control power supply
Output of inverter function
Relay operation
00
(Contact a)
On
ON
Close
OFF
Open
Off
-
Open
01
(Contact b)
On
ON
Open
OFF
Close
Off
-
Open
11
12
13
14
15
CM2
Inside of inverter
16A
16C
Inside of inverter
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......