8 - 177
8 Applied Settings
High-function General-purpose Inverter RX2 Series User’s Manual
8-1
1 Ou
tpu
t T
ermin
al Fu
n
ction
8
8-1
1-3 Output
Terminal ON
Dela
y/OFF
Delay
The specification of Relay 1c output terminals AL1 to AL0/AL2 to AL0 are as shown below.
• The operations of AL1 to AL0/AL2 to AL0 are as shown below.
You can set an on-delay/off-delay time per output terminal.
You can make a setting per output terminal. For the correspondence between output terminals and
parameters, please refer to the table shown on the below.
Precautions for Correct Use
All output signals immediately turn ON/OFF upon a condition is satisfied. Chattering could
occur depending on a selected signal. This function is available for retaining/delaying such a
signal.
Relay 1c Output Terminals
Resistance load
Induced load
AL1-AL0
Maximum contact capacity
AC250V, 2A
DC30V, 3A
AC250V, 0.2A
DC30V, 0.6A
Minimum contact capacity
AC100V, 10mA
DC5V, 100mA
AL2-AL0
Maximum contact capacity
AC250V, 1A
DC30V, 1A
AC250V, 0.2A
DC30V, 0.2A
Minimum contact capacity
AC100V, 10mA
DC5V, 100mA
[CC-17]
Control power
supply
Output of inverter
function
Output terminal state
AL1-AL0
AL2-AL0
00
On
ON
Close
Open
OFF
Open
Close
Off
-
Open
Close
01
(Initial value)
On
ON
Open
Close
OFF
Close
Open
Off
-
Open
Close
8-11-3 Output Terminal ON Delay/OFF Delay
Output terminals
On-delay time
Off-delay time
11
[CC-20]
[CC-21]
12
[CC-22]
[CC-23]
13
[CC-24]
[CC-25]
14
[CC-26]
[CC-27]
15
[CC-28]
[CC-29]
16A-16C
[CC-30]
[CC-31]
AL1-AL0/AL2-AL0
[CC-32]
[CC-33]
AL1
AL2
AL0
Inside of inverter
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......