8 Applied Settings
High-function General-purpose Inverter RX2 Series User’s Manual
8-1
1 Ou
tpu
t T
ermin
al Fu
n
ction
8
8-1
1-6 Output F
unction
s (
F
M)
2
When the standard point at which you want to perform outputs is the rated current value, since
the rated current has a maximum scale of Rated current × 2.00, set a point that is half of it. First
set [Cd-12] to 50.0% (corresponding to the inverter rated current).
In this state, since the full scale of the output current monitor is Rated current × 2.00, the [FM]
terminal outputs PWM of 50% duty, which is an output at the rated current (= Rated current ×
2.00 × 50.0%).
3
Adjust the inclination with [Cd-14]. Change [Cd-14] to make an adjustment toward the point from
which PWM of 100% duty is output.
(For example, see and wait with a range from 190.0% to 210.0%.)
[Cd-13]=0.0%, [Cd-14]=200.0%
4
Returning [Cd-10] to 00 starts the PWM output of [FM] that is adjusted.
t/T(%)
10 0
0
0A
50
Rated current × 2 (A)
Output current (A)
Rated current
(A)
t/T(%)
10 0
0
0A
50
[Cd -14]=200.0%
Rated current × 2 (A)
Output current (A)
Rated current
(A)
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......