9 Communications Functions
9 - 36
High-function General-purpose Inverter RX2 Series User’s Manual
0501h
Retry monitor 5 Factor
dE-35
R
1 to 255
1
0502h
0501h
Retry monitor 5 Output fre-
quency
-59000 to 59000
0.01(Hz)
0503h
0502h
(with sign)
0504h
0503h
Retry monitor 5 Output cur-
rent
0 to 65535
0.01(A)
0505h
0504h
Retry monitor 5 P-N DC volt-
age
0 to 10000
0.1(Vdc)
0506h
0505h
Retry monitor 5 Inverter
state
0 to 8
*5
1
0507h
0506h
Retry monitor 5 LAD state
0 to 5
*5
1
0508h
0507h
Retry monitor 5 INV control
mode
0 to 11
*5
1
0509h
0508h
Retry monitor 5 Limit state
0 to 6
*5
1
050Ah
0509h
Retry monitor 5 Special state
0 to 6
*5
1
050Ch
050Bh
Retry monitor 5 RUN time
0 to 1000000
1(hr)
050Dh
050Ch
050Eh
050Dh
Retry monitor 5 Power ON
time
0 to 1000000
1(hr)
050Fh
050Eh
0510h
050Fh
Retry monitor 5 Absolute
time (year, month)
00 to 99 (BCD code)
01 to 12 (BCD code)
-
0511h
0510h
Retry monitor 5 Absolute
time (day, day of the week)
01 to 31 (BCD code)
00 to 06 (BCD code)
-
0512h
0511h
Retry monitor 5 Absolute
time (hour, minute)
00 to 23 (BCD code)
00 to 59 (BCD code)
-
0515h
0514h
Retry monitor 6 Factor
dE-36
R
1 to 255
1
0516h
0515h
Retry monitor 6 Output fre-
quency
-59000 to 59000
0.01(Hz)
0517h
0516h
(with sign)
0518h
0517h
Retry monitor 6 Output cur-
rent
0 to 65535
0.01(A)
0519h
0518h
Retry monitor 6 P-N DC volt-
age
0 to 10000
0.1(Vdc)
051Ah
0519h
Retry monitor 6 Inverter
state
0 to 8
*5
1
051Bh
051Ah
Retry monitor 6 LAD state
0 to 5
*5
1
051Ch
051Bh
Retry monitor 6 INV control
mode
0 to 11
*5
1
051Dh
051Ch
Retry monitor 6 Limit state
0 to 6
*5
1
051Eh
051Dh
Retry monitor 6 Special state
0 to 6
*5
1
0520h
051Fh
Retry monitor 6 RUN time
0 to 1000000
1(hr)
0521h
0520h
0522h
0521h
Retry monitor 6 Power ON
time
0 to 1000000
1(hr)
0523h
0522h
0524h
0523h
Retry monitor 6 Absolute
time (year, month)
00 to 99 (BCD code)
01 to 12 (BCD code)
-
0525h
0524h
Retry monitor 6 Absolute
time (day, day of the week)
01 to 31 (BCD code)
00 to 06 (BCD code)
-
0526h
0525h
Retry monitor 6 Absolute
time (hour, minute)
00 to 23 (BCD code)
00 to 59 (BCD code)
-
Register
No.
Modbus
register
spec. No.
Function name
Parameter
No.
R/W
Monitor or setting data
Resolution
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......