9 Communications Functions
9 - 44
High-function General-purpose Inverter RX2 Series User’s Manual
2F4Fh
2F4Eh
Multispeed-1 setting
Ab-11
R/W
0 to 59000
0.01(Hz)
2F50h
2F4Fh
Multispeed-2 setting
Ab-12
R/W
0 to 59000
0.01(Hz)
2F51h
2F50h
Multispeed-3 setting
Ab-13
R/W
0 to 59000
0.01(Hz)
2F52h
2F51h
Multispeed-4 setting
Ab-14
R/W
0 to 59000
0.01(Hz)
2F53h
2F52h
Multispeed-5 setting
Ab-15
R/W
0 to 59000
0.01(Hz)
2F54h
2F53h
Multispeed-6 setting
Ab-16
R/W
0 to 59000
0.01(Hz)
2F55h
2F54h
Multispeed-7 setting
Ab-17
R/W
0 to 59000
0.01(Hz)
2F56h
2F55h
Multispeed-8 setting
Ab-18
R/W
0 to 59000
0.01(Hz)
2F57h
2F56h
Multispeed-9 setting
Ab-19
R/W
0 to 59000
0.01(Hz)
2F58h
2F57h
Multispeed-10 setting
Ab-20
R/W
0 to 59000
0.01(Hz)
2F59h
2F58h
Multispeed-11 setting
Ab-21
R/W
0 to 59000
0.01(Hz)
2F5Ah
2F59h
Multispeed-12 setting
Ab-22
R/W
0 to 59000
0.01(Hz)
2F5Bh
2F5Ah
Multispeed-13 setting
Ab-23
R/W
0 to 59000
0.01(Hz)
2F5Ch
2F5Bh
Multispeed-14 setting
Ab-24
R/W
0 to 59000
0.01(Hz)
2F5Dh
2F5Ch
Multispeed-15 setting
Ab-25
R/W
0 to 59000
0.01(Hz)
2FA9h
2FA8h
Acceleration/ Deceleration
Time input selection
AC-01
R/W
00: Parameter setting
01: Option 1
02: Option 2
03: Option 3
04: DriveProgramming
-
2FAAh
2FA9h
Acceleration/ Deceleration
Selection
AC-02
R/W
00: Common
01: Multi-stage accelera-
tion/deceleration
-
2FABh
2FAAh
Acceleration curve selection
AC-03
R/W
00: Linear
01: S-shaped
02: U-shaped
03: Reverse U-shaped
04: Elevator S-shaped
-
2FACh
2FABh
Deceleration curve selection
AC-04
R/W
00: Linear
01: S-shaped
02: U-shaped
03: Reverse U-shaped
04: Elevator S-shaped
-
2FADh
2FACh
Acceleration curve constant
setting
AC-05
R/W
1 to 10
1
2FAEh
2FADh
Deceleration curve constant
setting
AC-06
R/W
1 to 10
1
2FB0h
2FAFh
EL-S-curve ratio @start of
acceleration
AC-08
R/W
0 to 100
1(%)
2FB1h
2FB0h
EL-S-curve ratio @end of
acceleration
AC-09
R/W
0 to 100
1(%)
2FB2h
2FB1h
EL-S-curve ratio @start of
deceleration
AC-10
R/W
0 to 100
1(%)
2FB3h
2FB2h
EL-S-curve ratio @end of
deceleration
AC-11
R/W
0 to 100
1(%)
2FB7h
2FB6h
Select method to switch to
Accel2/Decel2 Profile,
1st-motor
AC115
R/W
00: [2CH] terminal
01: Parameter setting
02: Switching normal/reverse
rotation
-
2FB8h
2FB7h
Accel1 to Accel2 Frequency
transition point, 1st-motor
AC116
R/W
0 to 59000
0.01(Hz)
2FB9h
2FB8h
Decel1 to Decel2 Frequency
transition point, 1st-motor
AC117
R/W
0 to 59000
0.01(Hz)
Register
No.
Modbus
register
spec. No.
Function name
Parameter
No.
R/W
Monitor or setting data
Resolution
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......