9 - 59
9 Communications Functions
High-function General-purpose Inverter RX2 Series User’s Manual
9-
5 Mod
bu
s Com
m
u
n
icat
ion
Regi
ster Nu
m
b
er
List
9
9-5-
4 Group
A
Register
List
3211h
3210h
PID2 Deviation over level
AJ-17
R/W
0 to 10000
0.01(%)
3212h
3211h
PID2 Feedback compare sig-
nal turn-off level
AJ-18
R/W
0 to 10000
0.01(%)
3213h
3212h
PID2 Feedback compare sig-
nal turn-on level
AJ-19
R/W
0 to 10000
0.01(%)
3215h
3214h
PID3 enable
AJ-21
R/W
00 (Disabled)/
01 (Enabled Without reverse out-
put)/
02 (Enabled With reverse output)
-
3216h
3215h
PID3 deviation inverse
AJ-22
R/W
00: Disabled
01: Enabled
-
3217h
3216h
PID3 unit selection
AJ-23
R/W
See
C-70 at the end of Appendices C
-
3218h
3217h
PID3 scale adjustment (at
0%)
AJ-24
R/W
-10000 to 10000
1
3219h
3218h
PID3 scale adjustment (at
100%)
AJ-25
R/W
-10000 to 10000
1
321Ah
3219h
PID3 scale adjustment (point
position)
AJ-26
R/W
00:0000.
01:0000.0
02:000.00
03:00.000
04:0.0000
-
321Bh
321Ah
Input source selection of
Set-point for PID3
AJ-27
R/W
00: Disabled
01: Ai1 terminal input
02: Ai2 terminal input
03: Ai3 terminal input
04: (Reserved)
05: (Reserved)
06: (Reserved)
07: Parameter setting
08: RS 485
09: Option 1
10: Option 2
11: Option 3
12: Pulse string input: Inverter
13: Pulse string input: Option
-
321Eh
321Dh
Set-point setting for PID3
AJ-30
(HIGH)
R/W
-100.00 to 100.00
*4
Unit differs
depending
on setting
[AJ-23]
[AJ-26].
321Fh
321Eh
AJ-31
(LOW)
R/W
3220h
321Fh
Input source selection of Pro-
cess data for PID3
AJ-32
R/W
00: Disabled
01: Ai1 terminal input
02: Ai2 terminal input
03: Ai3 terminal input
04: (Reserved)
05: (Reserved)
06: (Reserved)
07: Parameter setting
08: RS 485
09: Option 1
10: Option 2
11: Option 3
12: Pulse string input: Inverter
13: Pulse string input: Option
-
Register
No.
Modbus
register
spec. No.
Function name
Parameter
No.
R/W
Monitor or setting data
Resolution
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......