9 - 65
9 Communications Functions
High-function General-purpose Inverter RX2 Series User’s Manual
9-
5 Mod
bu
s Com
m
u
n
icat
ion
Regi
ster Nu
m
b
er
List
9
9-5-
5 Group b
Register
List
32D4h
32D3h
Torque limit 1 (Forward driv-
ing), 1st-motor
bA112
R/W
0.0 to 500.0 (%)
(Limited at a torque equivalent to
200% of inverter ND rating)
0.1(%)
32D5h
32D4h
Torque limit 2 (Reverse
regenerative), 1st-motor
bA113
R/W
0.0 to 500.0 (%)
(Limited at a torque equivalent to
200% of inverter ND rating)
0.1(%)
32D6h
32D5h
Torque limit 3 (Reverse driv-
ing), 1st-motor
bA114
R/W
0.0 to 500.0 (%)
(Limited at a torque equivalent to
200% of inverter ND rating)
0.1(%)
32D7h
32D6h
Torque limit 4 (Forward regen-
erative), 1st-motor
bA115
R/W
0.0 to 500.0 (%)
(Limited at a torque equivalent to
200% of inverter ND rating)
0.1(%)
32D8h
32D7h
Torque limit LADSTOP
selection, 1st-motor
bA116
R/W
00: Disabled
01: Enabled
-
32DCh
32DBh
Over current suppress
enable, 1st-motor
bA120
R/W
00: Disabled
01: Enabled
-
32DDh
32DCh
Over current suppress Level,
1st-motor
bA121
R/W
(0.0 to 2.0)
× Inverter rated current
*1
0.1(A)
32Deh
32DDh
Overload restriction 1 mode
selection, 1st-motor
bA122
R/W
00: Disabled
01: Accelerate at constant speed
02: Only constant speed
03: Accelerate at constant
speed/Increase speed at regen-
eratio:n
-
32DFh
32Deh
Overload restriction 1 active
level, 1st-motor
bA123
R/W
(0.2 to 2.0)
× Inverter rated current
*1
0.1(A)
32E0h
32DFh
Overload restriction 1 action
time, 1st-motor
bA124
(HIGH)
R/W
10 to 360000
0.01(s)
32E1h
32E0h
bA125
(LOW)
R/W
32E2h
32E1h
Overload restriction 2 mode
selection, 1st-motor
bA126
R/W
00: Disabled
01: Accelerate at constant speed
02: Only constant speed
03: Accelerate at constant
speed/Increase speed at regen-
eratio:n
-
32E3h
32E2h
Overload restriction 2 active
level, 1st-motor
bA127
R/W
(0.2 to 2.0)
× Inverter rated current
*1
0.1(A)
32E4h
32E3h
Overload restriction 2 Action
time, 1st-motor
bA128
(HIGH)
R/W
10 to 360000
0.01(s)
32E5h
32E4h
bA129
(LOW)
R/W
32E6h
32E5h
Deceleration-stop at power
failure
bA-30
R/W
00 (Disabled)/
01 (Enabled: deceleration stop)/
02 (Enabled: no recovery)/
03 (Enabled: with recovery)
-
32E7h
32E6h
Decel-stop at power failure
starting voltage
bA-31
R/W
(200V class) 0- 4100
(400V class) 0- 8200
0.1(Vdc)
32E8h
32E7h
Decel-stop at power failure
control target level
bA-32
R/W
(200V class) 0- 4100
(400V class) 0- 8200
0.1(Vdc)
32Eah
32E9h
Decel-stop at power failure
deceleration time
bA-34
(HIGH)
R/W
1 to 360000
0.01(s)
32Ebh
32EAh
bA-35
(LOW)
R/W
Register
No.
Modbus
register
spec. No.
Function name
Parame-
ter No.
R/W
Monitor or setting data
Resolution
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......