9 Communications Functions
9 - 74
High-function General-purpose Inverter RX2 Series User’s Manual
370Eh
370Dh
Pulse train frequency Bias
value
CA-94
R/W
-1000 to 1000
0.1(%)
370Fh
370Eh
Pulse train frequency High
Limit
CA-95
R/W
0 to 1000
0.1(%)
3710h
370Fh
Pulse train frequency detec-
tion low level
CA-96
R/W
0 to 1000
0.1(%)
3711h
3710h
Comparing match output
ON-level for Pulse count
CA-97
R/W
0 to 65535
1
3712h
3711h
Comparing match output
OFF-level for Pulse count
CA-98
R/W
0 to 65535
1
3713h
3712h
Comparing match output
Maximum value for Pulse
count
CA-99
R/W
0 to 65535
1
3715h
3714h
Filter time constant of Termi-
nal [Ai1]
Cb-01
R/W
1 to 500
1(ms)
3717h
3716h
Start value of Terminal [Ai1]
Cb-03
R/W
0 to 10000
0.01(%)
3718h
3717h
End value of Terminal [Ai1]
Cb-04
R/W
0 to 10000
0.01(%)
3719h
3718h
Start rate of Terminal [Ai1]
Cb-05
R/W
0 to 1000 (Cb-06)
0.1(%)
371Ah
3719h
End rate of Terminal [Ai1]
Cb-06
R/W
(Cb-05) 0 to 1000
0.1(%)
371Bh
371Ah
Start point selection of Termi-
nal [Ai1]
Cb-07
R/W
00: Start amount
01: 0%
-
371Fh
371Eh
Filter time constant of Termi-
nal [Ai2]
Cb-11
R/W
1 to 500
1(ms)
3721h
3720h
Start value of Terminal [Ai2]
Cb-13
R/W
0 to 10000
0.01(%)
3722h
3721h
End value of Terminal [Ai2]
Cb-14
R/W
0 to 10000
0.01(%)
3723h
3722h
Start rate of Terminal [Ai2]
Cb-15
R/W
0 to 1000 (Cb-16)
0.1(%)
3724h
3723h
End rate of Terminal [Ai2]
Cb-16
R/W
(Cb-15) 0 to 1000
0.1(%)
3725h
3724h
Start point selection of Termi-
nal [Ai2]
Cb-17
R/W
00: Start amount
01: 0%
-
3729h
3728h
Filter time constant of Termi-
nal [Ai3]
Cb-21
R/W
1 to 500
1(ms)
372Ah
3729h
Terminal [Ai3] selection
Cb-22
R/W
00: Single
01: Added to Ai1/Ai2: with revers-
ibility
02: Added to Ai1/Ai2: without
reversibility
-
372Bh
372Ah
Start value of Terminal [Ai3]
Cb-23
R/W
-10000 to 10000
0.01%
372Ch
372Bh
End value of Terminal [Ai3]
Cb-24
R/W
-10000 to 10000
0.01%
372Dh
372Ch
Start rate of Terminal [Ai3]
Cb-25
R/W
-1000 to 1000 (Cb-26)
0.1(%)
372Eh
372Dh
End rate of Terminal [Ai3]
Cb-26
R/W
(Cb-25)-1000 to 1000
0.1(%)
3732h
3731h
[Ai1] Voltage/Current
zero-gain adjustment
Cb-30
R/W
-10000 to 10000
0.01(%)
3733h
3732h
[Ai1] Voltage/Current gain
adjustment
Cb-31
R/W
0 to 20000
0.01(%)
3734h
3733h
[Ai2] Voltage/Current
zero-gain adjustment
Cb-32
R/W
-10000 to 10000
0.01(%)
3735h
3734h
[Ai2] Voltage/Current gain
adjustment
Cb-33
R/W
0 to 20000
0.01(%)
3736h
3735h
[Ai3] Voltage/Current
zero-gain adjustment
Cb-34
R/W
-10000 to 10000
0.01(%)
3737h
3736h
[Ai3] Voltage gain adjustment
Cb-35
R/W
0 to 20000
0.01(%)
Register
No.
Modbus
register
spec. No.
Function name
Parameter
No.
R/W
Monitor or setting data
Resolution
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......