9 - 81
9 Communications Functions
High-function General-purpose Inverter RX2 Series User’s Manual
9-
5 Mod
bu
s Com
m
u
n
icat
ion
Regi
ster Nu
m
b
er
List
9
9-5-
7 Group H
Register
List
Precautions for Correct Use
Precautions for Correct Use
• The “Register No.” in the table header shows the register number used inside the inverter.
• The “Modbus register spec. No.” in the table header shows the register number used to actu-
ally specify the register in the Modbus communication process.
This register number is 1 less than the inverter “Register No.” according to the Modbus com-
munication specifications.
9-5-7
Group H Register List
Register
No.
Modbus
register
spec. No.
Function name
Parameter
No.
R/W
Monitor or setting data
Resolution
3A99h
3A98h
Auto-tuning selection
HA-01
R/W
00: Disabled
01: Non-rotation
02: Rotation
03: IVMS
-
3A9Ah
3A99h
RUN command selection at
Auto-tuning
HA-02
R/W
00: RUN key on LCD operator
01: [AA111]/[AA211]
-
3A9Bh
3A9Ah
Online auto-tuning selection
HA-03
R/W
00: Disabled
01: Enabled
-
3AA2h
3AA1h
Stabilization constant,
1st-motor
HA110
R/W
0 to 1000
1(%)
3AA7h
3AA6h
Speed response for Async. M,
1st-motor
HA115
R/W
0 to 1000
1(%)
3AACh
3AABh
ASR gain switching mode
selection, 1st-motor
HA120
R/W
00: [CAS] terminal
01: setting switch
-
3AADh
3AACh
ASR gain switching time set-
ting, 1st-motor
HA121
R/W
0 to 10000
1(ms)
3AAEh
3AADh
ASR gain mapping intermedi-
ate speed 1, 1st-motor
HA122
R/W
0 to 59000
0.01(Hz)
3AAFh
3AAEh
ASR gain mapping intermedi-
ate speed 2, 1st-motor
HA123
R/W
0 to 59000
0.01(Hz)
3AB0h
3AAFh
ASR gain mapping Maximum
speed, 1st-motor
HA124
R/W
0 to 59000
0.01(Hz)
3AB1h
3AB0h
ASR gain mapping P-gain 1,
1st-motor
HA125
R/W
0 to 10000
0.1(%)
3AB2h
3AB1h
ASR gain mapping I-gain 1,
1st-motor
HA126
R/W
0 to 10000
0.1(%)
3AB3h
3AB2h
ASR gain mapping P-gain 1
at P-control, 1st-motor
HA127
R/W
0 to 10000
0.1(%)
3AB4h
3AB3h
ASR gain mapping P-gain 2,
1st-motor
HA128
R/W
0 to 10000
0.1(%)
3AB5h
3AB4h
ASR gain mapping I-gain 2,
1st-motor
HA129
R/W
0 to 10000
0.1(%)
3AB6h
3AB5h
ASR gain mapping P-gain 2
at P-control, 1st-motor
HA130
R/W
0 to 10000
0.1(%)
3AB7h
3AB6h
ASR gain mapping P-gain 3,
1st-motor
HA131
R/W
0 to 10000
0.1(%)
3AB8h
3AB7h
ASR gain mapping I-gain 3,
1st-motor
HA132
R/W
0 to 10000
0.1(%)
3AB9h
3AB8h
ASR gain mapping P-gain 4,
1st-motor
HA133
R/W
0 to 10000
0.1(%)
3ABAh
3AB9h
ASR gain mapping I-gain 4,
1st-motor
HA134
R/W
0 to 10000
0.1(%)
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......