A - 11
Appendices A Technical Information
High-function General-purpose Inverter RX2 Series User’s Manual
A-2 Param
eter Co
m
p
arison
A
d102
DC voltage monitor
dA-40
d103
BRD load factor monitor
dA-41
d104
BRD thermal load factor monitor
dA-42
F001
Output frequency setting
FA-01
F002
First acceleration time setting
AC120
F202
Second acceleration time setting
AC220
F302
Third acceleration time setting
Abolition of third control
F003
First deceleration time setting
AC122
F203
Second deceleration time setting
AC222
F303
Third deceleration time setting
Abolition of third control
F004
Operation direction selection
AA-12
A001
Frequency command selection
AA101
Addition of individual settings for sec-
ond control
A002
Operation command selection
AA111
A003
First base frequency
Hb104/Hd104
Hb104: IM, Hd104: SM(PMM)
A203
Second base frequency
Hb204/Hd204
Hb204: IM, Hd204: SM(PMM)
A303
Third base frequency
Abolition of third control
A004
First maximum frequency
Hb105/Hd105
Hb105: IM, Hd105: SM(PMM)
A204
Second maximum frequency
Hb205/Hd205
Hb205: IM, Hd205: SM(PMM)
A304
Third maximum frequency
Abolition of third control
A005
AT terminal selection
This function is substituted by the set-
ting of AA101/AA102 and SCHG
(input terminal 015)
A006
O2 selection
This function is substituted by the set-
ting of Cb-22
A011
0 start
Cb-03
For Ai1
A012
0 end
Cb-04
For Ai1
A013
0 start ratio
Cb-05
For Ai1
A014
0 end ratio
Cb-06
For Ai1
A015
0 start selection
Cb-07
For Ai1
A016
Analog input filter
Cb-01
For Ai1 (Ai2: Cb-11, Ai3: Cb-21)
A017
Simplified sequence function selection
UE-02
A019
Multistep speed selection
Ab-03
A020
0th speed of the 1st multi-step speed
Ab110
A220
0th speed of the 2nd multi-step speed
Ab210
A320
0th speed of the 3rd multi-step speed
Abolition of third control
A021
1st speed of the multi-step speed
Ab-11
A022
2nd speed of the multi-step speed
Ab-12
A023
3rd speed of the multi-step speed
Ab-13
A024
4th speed of the multi-step speed
Ab-14
A025
5th speed of the multi-step speed
Ab-15
A026
6th speed of the multi-step speed
Ab-16
A027
7th speed of the multi-step speed
Ab-17
A028
8th speed of the multi-step speed
Ab-18
A029
9th speed of the multi-step speed
Ab-19
A030
10th speed of the multi-step speed
Ab-20
A031
11th speed of the multi-step speed
Ab-21
A032
12th speed of the multi-step speed
Ab-22
A033
13th speed of the multi-step speed
Ab-23
A034
14th speed of the multi-step speed
Ab-24
A035
15th speed of the multi-step speed
Ab-25
A038
Jogging frequency
AG-20
3G3RX-series V1
3G3RX2-series
Remarks
Display
code
Function name
New code
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......