Appendices A Technical Information
A - 14
High-function General-purpose Inverter RX2 Series User’s Manual
A105
OI start selection
Cb-17
For Ai2
A111
O2 start
Cb-23
For Ai3
A112
O2 end
Cb-24
For Ai3
A113
O2 start ratio
Cb-25
For Ai3
A114
O2 end ratio
Cb-26
For Ai3
A131
Acceleration curve constant
AC-05
A132
Deceleration curve constant
AC-06
A141
Operation frequency selection 1
AA101
Integrated into main speed/auxiliary
speed command.
Addition of individual settings for sec-
ond control
A142
Arithmetic operation frequency selection 2
AA102
Integrated into main speed/auxiliary
speed command.
Addition of individual settings for sec-
ond control
A143
Arithmetic operation operator selection
AA105
Addition of individual settings for sec-
ond control
A145
Additional frequency setting
AA106
Addition of individual settings for sec-
ond control
A146
Additional frequency sign selection
You can change the sign by setting
AA106 with ±.
A150
Curvature 1 for EL-S-shaped acceleration
AC-08
A151
Curvature 2 for EL-S-shaped acceleration
AC-09
A152
Curvature 1 for EL-S-shaped deceleration
AC-10
A153
Curvature 2 for EL-S-shaped deceleration
AC-11
b001
Selection of instantaneous power failure/
undervoltage restart
bb-24
Specify b001=00 (trip) with retry count
(instantaneous power failure
[bb-20]/undervoltage [bb-21]) with
zero.
b002
Allowable instantaneous power failure time
bb-25
b003
Retry stand-by time for instantaneous
power failure and insufficient voltage
bb-26
b004
Instantaneous power failure/undervoltage
tripping selection during stop
bb-27
b005
Selection of instantaneous power failure
retry count
bb-20
0: trip, 255: infinite
b006
Input phase loss selection
bb-65
b007
f matching lower limit frequency setting
bb-42
b008
Trip retry selection
bb-28
Specify b008=00 (trip) with retry count
(overvoltage [bb-22]/undercurrent
[bb-23]) with zero.
b009
Selection of undervoltage retry count
bb-21
0: trip, 255: infinite
b010
Selection of overvoltage/overcurrent retry
count
bb-22
bb-23
Specify overvoltage [bb-22] and over-
current [bb-23] individually.
b011
Trip retry standby time
bb-29
b012
First electronic thermal level
bC110
b212
Second electronic thermal level
bC210
b312
Third electronic thermal level
Abolition of third control
b013
Selection of first electronic thermal charac-
teristics
bC111
b213
Selection of second electronic thermal
characteristics
bC211
3G3RX-series V1
3G3RX2-series
Remarks
Display
code
Function name
New code
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......