C - 23
Appendices C Table of Parameters
High-function General-purpose Inverter RX2 Series User’s Manual
C-
3 Paramet
er List
C
Code
Codes that
can be
changed
during
operation
Name
Data range
Initial
value
Note
Ab-01
-
Frequency conversion gain
0.01 to 100.00
1.00
Ab-03
-
Multistep speed selection
00 (16th speed: binary (CF1 to CF4))/
01 (8th speed: bit (SF1 to SF7))
00
Ab110
○
Multispeed-0 setting, 1st-motor
0.00 to 590.00 (Hz)
0.00
Ab-11
○
Multispeed-1 setting
0.00 to 590.00 (Hz)
0.00
Ab-12
○
Multispeed-2 setting
0.00 to 590.00 (Hz)
0.00
Ab-13
○
Multispeed-3 setting
0.00 to 590.00 (Hz)
0.00
Ab-14
○
Multispeed-4 setting
0.00 to 590.00 (Hz)
0.00
Ab-15
○
Multispeed-5 setting
0.00 to 590.00 (Hz)
0.00
Ab-16
○
Multispeed-6 setting
0.00 to 590.00 (Hz)
0.00
Ab-17
○
Multispeed-7 setting
0.00 to 590.00 (Hz)
0.00
Ab-18
○
Multispeed-8 setting
0.00 to 590.00 (Hz)
0.00
Ab-19
○
Multispeed-9 setting
0.00 to 590.00 (Hz)
0.00
Ab-20
○
Multispeed-10 setting
0.00 to 590.00 (Hz)
0.00
Ab-21
○
Multispeed-11 setting
0.00 to 590.00 (Hz)
0.00
Ab-22
○
Multispeed-12 setting
0.00 to 590.00 (Hz)
0.00
Ab-23
○
Multispeed-13 setting
0.00 to 590.00 (Hz)
0.00
Ab-24
○
Multispeed-14 setting
0.00 to 590.00 (Hz)
0.00
Ab-25
○
Multispeed-15 setting
0.00 to 590.00 (Hz)
0.00
Ab210
○
Multispeed-0 setting, 2nd-motor
0.00 to 590.00 (Hz)
0.00
Code
Codes that
can be
changed
during
operation
Name
Data range
Initial
value
Note
AC-01
-
Acceleration/ Deceleration time
input selection
00 (Parameter setting)/01 (Option 1)/
02 (Option 2)/03 (Option 3)/04 (DriveProgramming)
00
AC-02
-
Acceleration/ Deceleration
Selection
00 (Common)/
01 (Multi-stage acceleration/deceleration)
00
AC-03
-
Acceleration curve selection
00 (Linear)/01 (S-shaped)/02 (U-shaped)/
03 (Reverse U-shaped)/04 (Elevator S-shaped)
00
AC-04
-
Deceleration curve selection
00 (Linear)/01 (S-shaped)/02 (U-shaped)/
03 (Reverse U-shaped)/04 (Elevator S-shaped)
00
AC-05
-
Acceleration curve constant set-
ting
1 to 10
2
AC-06
-
Deceleration curve constant set-
ting
1 to 10
2
AC-08
-
EL-S-curve ratio @start of
acceleration
0 to 100
25
AC-09
-
EL-S-curve ratio @end of accel-
eration
0 to 100
25
AC-10
-
EL-S-curve ratio @start of
deceleration
0 to 100
25
AC-11
-
EL-S-curve ratio @end of decel-
eration
0 to 100
25
AC115
-
Select method to switch to
Accel2/Decel2 Profile, 1st-motor
00 ([2CH] terminal)/01 (Parameter setting)/
02 (Switching normal/reverse rotation)
00
AC116
○
Accel1 to Accel2 Frequency
transition point, 1st-motor
0.00 to 590.00 (Hz)
0.00
AC117
○
Decel1 to Decel2 Frequency
transition point, 1st-motor
0.00 to 590.00 (Hz)
0.00
AC120
○
Acceleration time setting 1,
1st-motor
0.00 to 3600.00 (s)
30.00
AC122
○
Deceleration time setting 1,
1st-motor
0.00 to 3600.00 (s)
30.00
AC124
○
Acceleration time setting 2,
1st-motor
0.00 to 3600.00 (s)
15.00
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......