C - 25
Appendices C Table of Parameters
High-function General-purpose Inverter RX2 Series User’s Manual
C-
3 Paramet
er List
C
AC-88
○
Deceleration time setting for
multi-speed 15
0.00 to 3600.00 (s)
0.00
AC215
-
Select method to switch to
Accel2/Decel2 Profile,
2nd-motor
00 ([2CH] terminal)/01 (Parameter setting)/
02 (Switching normal/reverse rotation)
00
AC216
○
Accel1 to Accel2 Frequency
transition point, 2nd-motor
0.00 to 590.00 (Hz)
0.00
AC217
○
Decel1 to Decel2 Frequency
transition point, 2nd-motor
0.00 to 590.00 (Hz)
0.00
AC220
○
Acceleration time setting 1,
2nd-motor
0.00 to 3600.00 (s)
30.00
AC222
○
Deceleration time setting 1,
2nd-motor
0.00 to 3600.00 (s)
30.00
AC224
○
Acceleration time setting 2,
2nd-motor
0.00 to 3600.00 (s)
15.00
AC226
○
Deceleration time setting 2,
2nd-motor
0.00 to 3600.00 (s)
15.00
Code
Codes that
can be
changed
during
operation
Name
Data range
Initial
value
Note
Ad-01
-
Torque reference input source
selection
01 (Ai1 terminal input)/02 (Ai2 terminal input)/
03 (Ai3 terminal input)/04 (Reserved)/05 (Reserved)/
06 (Reserved)/07 (Parameter setting)/08 (RS 485)/
09 (Option 1)/10 (Option 2)/11 (Option 3)/
12 (Pulse string input: main unit)/
13 (Pulse string input: Option)/15 (PID calculation)
07
Ad-02
○
Torque reference value setting
-500.0 to 500.0 (%)
(Limited at a torque equivalent to 200% of inverter ND rat-
ing)
0.0
Ad-03
-
Polarity selection for torque ref-
erence
00 (As per the sign)/
01 (Follow the revolution direction)
00
Ad-04
○
Switching time of Speed control
to Torque control
0 to 1000 (ms)
100
Ad-11
-
Torque bias input source selec-
tion
00 (Disabled)/01 (Ai1 terminal input)/02 (Ai2 terminal input)/
03 (Ai3 terminal input)/04 (Reserved)/05 (Reserved)/
06 (Reserved)/07 (Parameter setting)/08 (RS 485)/
09 (Option 1)/10 (Option 2)/11 (Option 3)/
12 (Pulse string input: main unit)/
13 (Pulse string input: Option)/15 (PID calculation)
00
Ad-12
○
Torque bias value setting
-500.0 to 500.0 (%)
(Limited at a torque equivalent to 200% of inverter ND rat-
ing)
0.0
Ad-13
-
Polarity selection for torque bias
00 (As per the sign)/
01 (Follow the revolution direction)
00
Ad-14
-
Terminal [TBS] active
00 (Disabled)/01 (Enabled)
00
Ad-40
-
Input selection for speed limit at
torque control
01 (Ai1 terminal input)/02 (Ai2 terminal input)/
03 (Ai3 terminal input)/04 (Reserved)/05 (Reserved)/
06 (Reserved)/07 (Parameter setting)/08 (RS 485)/
09 (Option 1)/10 (Option 2)/11 (Option 3)/
12 (Pulse string input: main unit)/
13 (Pulse string input: Option)
07
Ad-41
○
Speed limit at torque control (at
Forward rotation)
0.00 to 590.00 (Hz)
0.00
Ad-42
○
Speed limit at torque control (at
Reverse rotation)
0.00 to 590.00 (Hz)
0.00
Code
Codes that
can be
changed
during
operation
Name
Data range
Initial
value
Note
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......