C - 43
Appendices C Table of Parameters
High-function General-purpose Inverter RX2 Series User’s Manual
C-
3 Paramet
er List
C
CA-70
○
Speed reference source selection at
[F-OP] is active
01 (Ai1 terminal input)/02 (Ai2 terminal input)/
03 (Ai3 terminal input)/04 (Reserved)/
05 (Reserved)/06 (Reserved)/
07 (Parameter setting)/08 (RS 485)/09 (Option 1)/
10 (Option 2)/11 (Option 3)/
12 (Pulse string input: main unit)/
13 (Pulse string input: Option)/14 (Program function)/
15 (PID calculation)/16 (Reserved)
01
CA-71
○
RUN command source selection at
[F-OP] is active
00 ([FW]/[RV] terminal)/01 (3 wire)/
02 (RUN key on operator keypad)/
03 (RS485)/04 (Option 1)/05 (Option 2)/06 (Option 3)/
00
CA-72
-
Reset mode selection
00 (On to Release Trip)/01 (Off to Release Trip)/
02 (On to Release at Trip)/03 (Off to Release at Trip)
00
CA-81
-
Encoder constant setting
32 to 65535 (pls)
1024
CA-82
-
Encoder position selection
00 (Phase-A is leading)/
01 (Phase-B is leading)
00
CA-83
-
Motor gear ratio Numerator
1 to 10000
1
CA-84
-
Motor gear ratio Denominator
1 to 10000
1
CA-90
-
Pulse train detection object selection
00 (Disabled)/01 (Frequency command)/
02 (Speed feedback)/03 (Pulse count)
00
CA-91
-
Mode selection of pulse train input
00 (90° phase difference)/
01 (forward/reverse rotation command and rotation
direction)/
02 (forward/reverse rotation pulse string)
00
CA-92
○
Pulse train frequency Scale
0.05 to 32.00 (kHz)
25.00
CA-93
○
Pulse train frequency Filter time con-
stant
0.01 to 2.00 (s)
0.10
CA-94
○
Pulse train frequency Bias value
-100.0 to 100.0 (%)
0.0
CA-95
○
Pulse train frequency High Limit
0.0 to 100.0 (%)
100.0
CA-96
○
Pulse train frequency detection low
level
0.0 to 100.0 (%)
0.0
CA-97
○
Comparing match output ON-level for
Pulse count
0 to 65535
0
CA-98
○
Comparing match output OFF-level
for Pulse count
0 to 65535
0
CA-99
○
Comparing match output Maximum
value for Pulse count
0 to 65535
65535
Code
Codes that
can be
changed
during
operation
Name
Data range
Initial
value
Note
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......