Appendices C Table of Parameters
C - 46
High-function General-purpose Inverter RX2 Series User’s Manual
Code
Codes that
can be
changed
during
operation
Name
Data range
Initial
value
Note
Cb-01
○
Filter time constant of Terminal [Ai1]
1 to 500 (ms)
16
Cb-03
○
Start value of Terminal [Ai1]
0.00 to 100.00 (%)
0.00
Cb-04
○
End value of Terminal [Ai1]
0.00 to 100.00 (%)
100.00
Cb-05
○
Start rate of Terminal [Ai1]
0.0 to [Cb-06] (%)
0.0
Cb-06
○
End rate of Terminal [Ai1]
[Cb-05] to 100.0 (%)
100.0
Cb-07
○
Start point selection of Terminal [Ai1]
00 (Start amount)/01 (0%)
01
Cb-11
○
Filter time constant of Terminal [Ai2]
1 to 500 (ms)
16
Cb-13
○
Start value of Terminal [Ai2]
0.00 to 100.00 (%)
0.00
Cb-14
○
End value of Terminal [Ai2]
0.00 to 100.00 (%)
100.00
Cb-15
○
Start rate of Terminal [Ai2]
0.0 to [Cb-16] (%)
20.0
Cb-16
○
End rate of Terminal [Ai2]
[Cb-15] to 100.0 (%)
100.0
Cb-17
○
Start point selection of Terminal [Ai2]
00 (Start amount)/01 (0%)
01
Cb-21
○
Filter time constant of Terminal [Ai3]
1 to 500 (ms)
16
Cb-22
-
Terminal [Ai3] selection
00 (Single)/
01 (Added to Ai1/Ai2: with reversibility)/
02 (Added to Ai1/Ai2: without reversibility)
00
Cb-23
○
Start value of Terminal [Ai3]
-100.00 to 100.00 (%)
-100.00
Cb-24
○
End value of Terminal [Ai3]
-100.00 to 100.00 (%)
100.00
Cb-25
○
Start rate of Terminal [Ai3]
-100.0 to [Cb-26]
-100.0
Cb-26
○
End rate of Terminal [Ai3]
[Cb-25] to 100.0
100.0
Cb-30
-
[Ai1] Voltage/Current zero-gain
adjustment
-100.00 to 100.00
0.00
Cb-31
-
[Ai1] Voltage/Current gain adjustment
0 to 200.00
100.00
Cb-32
-
[Ai2] Voltage/Current zero-gain
adjustment
-100.00 to 100.00
0.00
Cb-33
-
[Ai2] Voltage/Current gain adjustment
0 to 200.00
100.00
Cb-34
-
[Ai3] Voltage/Current zero-gain
adjustment
-100.00 to 100.00
0.00
Cb-35
-
[Ai3] Voltage gain adjustment
0 to 200.00
100.00
Cb-40
○
Thermistor selection
00 (Disabled)/
01 (PTC resistance value enabled)/
02 (NTC resistance value enabled)
00
Cb-41
-
Thermistor gain adjustment
0.0 to 1000.0
100.0
Cb-51 to
Cb-57
-
Reserved
-
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......