Appendices C Table of Parameters
C - 60
High-function General-purpose Inverter RX2 Series User’s Manual
Hb257
-
Free-V/f Voltage 4 setting,
2nd-motor
0.0 to 1000.0 (V)
0.0
Hb258
-
Free-V/f frequency 5 setting,
2nd-motor
[Hb256] to [Hb260] (Hz)
0.00
Hb259
-
Free-V/f Voltage 5 setting,
2nd-motor
0.0 to 1000.0 (V)
0.0
Hb260
-
Free-V/f frequency 6 setting,
2nd-motor
[Hb258] to [Hb262] (Hz)
0.00
Hb261
-
Free-V/f Voltage 6 setting,
2nd-motor
0.0 to 1000.0 (V)
0.0
Hb262
-
Free-V/f frequency 7 setting,
2nd-motor
[Hb260] to [Hb204] (Hz)
0.00
Hb263
-
Free-V/f Voltage 7 setting,
2nd-motor
0.0 to 1000.0 (V)
0.0
Hb270
○
Slip Compensation P-gain with
encoder, 2nd-motor
0 to 1000 (%)
100
Hb271
○
Slip Compensation I-gain with
encoder, 2nd-motor
0 to 1000 (%)
100
Hb280
○
Output voltage gain,
2nd-motor(V/f)
0 to 255 (%)
100
*1. Varies depending on inverter models and settings of duty rating.
*2. It is a default value when Default Value Selection (Ub-02) is set to 01.
Code
Codes that
can be
changed
during
operation
Name
Data range
Initial
value
Note
HC101
○
Automatic torque boost voltage com-
pensation gain, 1st-motor
0 to 255 (%)
100
HC102
○
Automatic torque boost slip compensa-
tion gain, 1st-motor
0 to 255 (%)
100
HC110
○
Zero speed area limit for
Async.M-0SLV, 1st-motor
0 to 100 (%)
80
HC111
○
Boost value at start for
Async.M-SLV/IM-CLV, 1st-motor
0 to 50 (%)
0
HC112
○
Boost value at start for Async.M-0SLV,
1st-motor
0 to 50 (%)
10
HC113
-
Secondary resistance correction,
1st-motor
00 (Disabled)/01 (Enabled)
00
HC114
○
Counter direction run protection selec-
tion, 1st-motor
00 (Disabled)/01 (Enabled)
00
HC120
○
Torque current reference filter time con-
stant, 1st-motor
0 to 100 (ms)
2
HC121
○
Speed feedforward compensation gain,
1st-motor
0 to 1000
0
HC201
○
Automatic torque boost voltage com-
pensation gain, 2nd-motor
0 to 255 (%)
100
HC202
○
Automatic torque boost slip compensa-
tion gain, 2nd-motor
0 to 255 (%)
100
HC210
○
Zero speed area limit for
Async.M-0SLV, 2nd-motor
0 to 100 (%)
80
HC211
○
Boost value at start for
Async.M-SLV/IM-CLV, 2nd-motor
0 to 50 (%)
0
HC212
○
Boost value at start for Async.M-0SLV,
2nd-motor
0 to 50 (%)
10
HC213
-
Secondary resistance correction,
2nd-motor
00 (Disabled)/01 (Enabled)
00
HC214
○
Counter direction run protection selec-
tion, 2nd-motor
00 (Disabled)/01 (Enabled)
00
Code
Codes that
can be
changed
during
operation
Name
Data range
Initial value
Note
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Page 919: ......