Appendices C Table of Parameters
C - 66
High-function General-purpose Inverter RX2 Series User’s Manual
Parameter Mode (Code U)
Code
Codes that
can be
changed
during
operation
Name
Data range
Initial
value
Note
UA-01
-
Password input for display
selection
-
0000
UA-02
-
Soft-lock password input
-
0000
UA-10
-
Display restriction selection
00 (Full display)/01 (By function)/02 (User setting)/
03 (Conveyor display)/04 (Only monitor display)
00
UA-12
○
Accumulation input power moni-
tor clear
00 (Disabled)/01 (Clear)
00
UA-13
○
Display gain for Accumulation
input power monitor
1 to 1000
1
UA-14
○
Accumulation output power
monitor clear
00 (Disabled)/01 (Clear)
00
UA-15
○
Display gain for Accumulation
output power monitor
1 to 1000
1
UA-16
○
Soft-lock selection
00 ([SFT] terminal)/01 (Always enabled)
00
UA-17
○
Soft-lock target selection
00 (All data cannot be changed)/
01 (Data other than set frequency cannot be changed)
00
UA-18
-
Data R/W selection
00 (R/W enabled)/01 (R/W disabled)
00
UA-19
-
Low battery warning enable
00 (Disabled)/01 (Warning)/02 (Error)
00
UA-20
-
Action selection at Keypad dis-
connection
00 (Error)/01 (Error after deceleration stop)/02 (Ignore)/
03 (Free run)/04 (Deceleration stop)
02
UA-21
-
2nd-motor parameter display
selection
00 (Not display/01 (Display)
01
UA-22
-
Option parameter display selec-
tion
00 (Not display/01 (Display)
01
UA-30
-
User parameter auto setting
function enable
00 (Disabled)/01 (Enabled)
00
UA-31
○
User parameter 1 selection
no/***** (select a parameter)
no
UA-32
○
User parameter 2 selection
no/***** (select a parameter)
no
UA-33
○
User parameter 3 selection
no/***** (select a parameter)
no
UA-34
○
User parameter 4 selection
no/***** (select a parameter)
no
UA-35
○
User parameter 5 selection
no/***** (select a parameter)
no
UA-36
○
User parameter 6 selection
no/***** (select a parameter)
no
UA-37
○
User parameter 7 selection
no/***** (select a parameter)
no
UA-38
○
User parameter 8 selection
no/***** (select a parameter)
no
UA-39
○
User parameter 9 selection
no/***** (select a parameter)
no
UA-40
○
User parameter 10 selection
no/***** (select a parameter)
no
UA-41
○
User parameter 11 selection
no/***** (select a parameter)
no
UA-42
○
User parameter 12 selection
no/***** (select a parameter)
no
UA-43
○
User parameter 13 selection
no/***** (select a parameter)
no
UA-44
○
User parameter 14 selection
no/***** (select a parameter)
no
UA-45
○
User parameter 15 selection
no/***** (select a parameter)
no
UA-46
○
User parameter 16 selection
no/***** (select a parameter)
no
UA-47
○
User parameter 17 selection
no/***** (select a parameter)
no
UA-48
○
User parameter 18 selection
no/***** (select a parameter)
no
UA-49
○
User parameter 19 selection
no/***** (select a parameter)
no
UA-50
○
User parameter 20 selection
no/***** (select a parameter)
no
UA-51
○
User parameter 21 selection
no/***** (select a parameter)
no
UA-52
○
User parameter 22 selection
no/***** (select a parameter)
no
UA-53
○
User parameter 23 selection
no/***** (select a parameter)
no
UA-54
○
User parameter 24 selection
no/***** (select a parameter)
no
UA-55
○
User parameter 25 selection
no/***** (select a parameter)
no
UA-56
○
User parameter 26 selection
no/***** (select a parameter)
no
UA-57
○
User parameter 27 selection
no/***** (select a parameter)
no
Summary of Contents for RX - 2
Page 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Page 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Page 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Page 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Page 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Page 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...